Installation must be performed by qualified technicians according to the law in force.
See technical date tables : 1.1 and 2.5-2.6.
WARNINGS:
Should the unit be installed against a wall, the latter must be heat-resistant to temperatures of 100°C and must be
fireproof, or it has to be placed at a distance of 10 cm.
Before proceeding with the installation, remove the protective plastic film from the relevant parts, eliminating any
adhesive residues with an appropriate cleaning product suitable for stainless steel.
Install the unit in a horizontal position; its correct levelling will be achieved by rotating the adjustable feet.
If the unit is installed by itself, it is advisable to fasten it to make its stability safer : especially for models F15G/M
NOTE: it is strictly fobidden to remove the feet of the fryer and install it on a cement base
2.1

INFORMATION ABOUT GAS FRYER

This manual applies to our Gas Fryers , Type A Category II (Natural Gas and L.P.G.).
See table 1.1 and 2.5-2.6.
The label according to EN437 and EN203 regulations, Part 1, is located:
a) inner door side
Example for Italy label:
Category II 2H3÷
Pe = Incoming Pressure
Pi = Nozzle Pressure
2.2

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE COMPLIED WITH

The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the Gas Supply Company, which should issue an authorisation before installation.
- Instructions for the "Installation of gas equipment"
- Hygienic regulations.
2.3

INSTALLATION PLACE

- The unit should be installed in adequately ventilated places. (This unit requires a draft of at least 2 cu.m/hr x kW P.T.
(Thermal capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed.
2.4

POSITIONING

- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.
GB
V
IT-GR-GB-ES-IE
PT
II2H3+
II2H3+
Cat.
P n
20,29/37
20,29/37
LU
IS-DK-FI-SE
Cat.
II2E3P
II2H3B/P
P n
20,37,50
20,29
G20
Qn
kW
(Hi)
G25
- 18 -

INSTALLATION INSTRUCTIONS

Mod.
Matr.N°
Hz
kW
FR-BE
NL
II2E+3+
II2L3P
20/25,29/37
25,30,50
AT-CH
DE
II2H3B/P
II2ELL3B/P
20,50
20,20,50
m
3
/h
G30
3
m
/h
G31
Type
tipo
mbar
mbar
NO
I3P
30
Kg/h
Kg/h