XXX-78100 SENSOR (XX-781)
To decrease the day temperature level or to increase the night temperature level, proceed as follows:
Step Action
or till the standard day or night temperature. Day or night temperature is displayed.
1
Press
2
Briefly release
or
.
3
Press
or
till the desired temperature.
4
Press
to confirm.
B. Switching from manual to automatic mode
As long as a hand symbol is blinking on the display, the clock thermostat is in manual mode. The manual mode
will be switched off when a control command is carried out. To switch from the manual mode to the automatic
mode, proceed as follows:
Step Action
Press
or
till the standard day, night or
1
antifreeze temperature.
2
Briefly release
or
.
3
Press
to switch to automatic mode.
C. Setting day or week programs
The memory locations below are the standard settings.
program
Time
temperature level
01
07h00
02
23h00
The factory set program sets the day temperature at 07h00 and the night temperature at 23h00. You can,
however, set up an individual program that is adapted to your personal rhythm. For this purpose, the unit has
24 memory locations. Each memory location contains the elements 'switch time', 'weekday'/'week block' and
'temperature level'.
Adding a switch command
Step Action
1
Press for 3s
to enter programming mode. The unit displays the first memory location (01).
2
Briefly press
to set weekday/block.
3
Press
or
.
Press
to select day, night or antifreezing
4
temperature.
5
Press
.
6
Press
.
Remark: when the memory location after a free memory location is selected, the number of free memory
locations appears on the display, e.g.: rE21 = 21 free memory locations.
Modifying a switch command
Step Action
1
to enter programming mode. The unit displays the first memory location (01).
Press for 3s
Briefly press until the desired memory
2
location is selected.
Briefly press
to set weekday or week-
3
block.
4
Press
or
.
Press
to select day, night or antifreezing
5
temperature.
6
Press
.
Deleting a switch command
Step Action
1
Press for 3s
to enter programming mode.
Briefly press
until the desired program is
2
selected.
3
Press
and
simultaneously.
4
Press
.
Deleting all settings and returning to fabric settings
To delete all the programs and settings carried out by the user:
Action
Result
All programs and settings will be deleted. Return to fabric settings.
Keep
pressed and briefly press .
nv Niko sa
Result
Day or night temperature blinks.
Desired temperature is displayed.
Return to starting screen, the current
temperature is displayed.
Result
Day, night or antifreeze temperature is displayed.
Day, night or antifreeze temperature blinks.
Return to starting screen, hand symbol dissapears.
Temperature
Day
Day
20°C
1234567
Night
15°C
1234567
Result
The order is as follows:
- 'full week' block Mo. - Sun. (1234567)
- 'long working week' block Mo. - Sat. (123456)
- 'short working week' block Mo. - Fri. (12345)
- 'long weekend' block Fri. / Sun. (567)
- 'short weekend' block Sat. - Sun. (67)
- individual weekdays Mo., Tue. etc.... (1, 2, 3, 4, 5, 6, 7)
Increase/decrease switching time.
Sun, moon or ice crystal appears on the left side of the
display.
The next memory location is called up.
Return to starting screen
Result
The memory location to be changed, is selected.
The order is as follows:
- 'full week' block Mo. - Sun. (1234567)
- 'long working week' block Mo. - Sat. (123456)
- 'short working week' block Mo. - Fri. (12345)
- 'long weekend' block Fri. / Sun. (567)
- 'short weekend' block Sat. - Sun. (67)
- individual weekdays Mo., Tue. etc.... (1, 2, 3, 4, 5, 6, 7)
Increase/decrease switching time.
Sun, moon or ice crystal appears on the left side of the
display.
Return to starting screen
Result
The unit displays the first memory location (01).
The memory location to be removed is selected.
Content of the selected memory location is removed.
Return to starting screen
Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@Niko.be — www.niko.be
D. Functions with external switch
In combination with an actor, allowing for an external switch, connected on E1, the switch will have following
function:
• switch OFF: normal operation
• switch ON: night temperature level active (hand symbol visible)
Attention: for as long as the switch is at ON, the night temperature will remain active! In this mode the ther-
mostat can only be programmed or reset.
7. CAuTION DuRING OpERATION
• In case of troubles, use the RESET button. The program remains in memory.
• After ±10min, a stable temperature is displayed. This phenomenon is perfectly normal, it doesn' t indicate a
defect.
• The clock thermostat cannot not be used to directly control a liquid fuel burner. The clock thermostat is used
to activate the circulation pump for the central heating.
• Many factors could influence a temperature measurement. In order to guarantee a correct temperature
measurement, the following must be taken into account:
- Do not place the thermostat on a wall that is in direct contact with the outside air.
- Do not place the thermostat in the immediate vicinity of a heating source (stove, heating,...) or an electrical
device that radiates heat (TV, computer, ...).
- Do not place the thermostat in direct sunlight or artificial light.
- Do not place the thermostat behind a curtain or drapery.
- Avoid air circulation in the pipes of the heating installation. Fill possible holes with PU-foam.
Rp
1
1
8. TROuBlESHOOTING
The 'flame' symbol is shown on the display, even if the temperature in the room has already been reached. The
thermostat is provided with a digital control and anticipates temperature fluctuations. As the pump needs some
time to heat the room, the thermostat controls the pump in advance and remains active for some time after
the set temperature has been reached. This enables to have a steady temperature, which results in maximum
return and minimum consumption.

9. lEGAl WARNINGS

- Read the complete manual before attempting installation and activating the system.
- The installation has to be carried out by a registered installer and in compliance with the statutory regulations.
- This user manual has to be handed over to the user. It has to be included in the electrical installation file and
has to be passed on to any new owners. Additional copies are available on the Niko website or via the support
service.
- During installation, the following has to be taken into account (not limited to list below):
- The statutory laws, standards and regulations;
- The state of the art technique at the moment of installation;
- This user manual, which must be read within the scope of each specific installation, only states general
regulations;
- The rules of proper workmanship
- In case of questions, you can consult Niko's support service or contact a registered control organisation.
Support Belgium:
+32 3 778 90 80
website : http://www.niko.be
e-mail: support@niko.be
In case of a defect, you can return your product to a registered Niko wholesaler, together with a clear description
of your complaint (Conditions of use, stated defect...).

10. GuARANTEE pROVISIONS

- Period of guarantee: 2 years from date of delivery. The delivery date is the invoice date of purchase of the
product by the consumer. If there is no invoice, the date of production applies.
- The consumer is obliged to inform Niko in writing about the defect, within two months after stating the
defect.
- In case of a failure to conform, the consumer has the right to a repair or replacement (decided by Niko) free of
charge.
- Niko cannot be held liable for a defect or damage as a result of an incorrect installation, improper or careless
use or wrong usage or transformation of the goods.
- The compulsory regulations of the national legislation concerning the sales of consumer goods and the protection
of the consumers in the countries where Niko sells, directly or via sister or daughter companies, chain stores,
distributors, agents or permanent sales representatives, take priority over the rules and regulations mentioned
above.

11. WIRING DIAGRAM

See technical details of the corresponding actors.
XXX-78100
1,50m
Support UK:
+44 1525877707
http://www.nikouk.com
sales@nikouk.com
PMXXX-78100R08171

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Xx-781781 serie

Table des Matières