Gun Cleaner – topping up with solvent
1. Open the lid of the Gun Cleaner.
2. Top up with 40-45 litres of solvent poured directly into the Gun Cleaner.
Recycler – topping up with solvent
1. Remove the three clips from the cover of the distillate container and remove the cover. Take care to avoid damaging the
level indicator float.
2. Fill the distillate container with 12 litres of clean solvent, i.e. up to 100 mm from the top edge.
3. Refit the cover and secure it with the three clips.

Operating manual

This manual and the manuals for the Gun Cleaner and the Recycler must always be kept available and in legible condition by the
system. Pin up the plastic-covered operating manual (no. 11151) so that it is clearly visible in the immediate vicinity of the
Recycler. If necessary, it must also be translated into other languages spoken by the employees.
Service personnel
It is essential that the personnel gets special training in the system´s use. Only personnel who have undergone such training may
use the system.
Starting up for the first time
The system can now be taken into operation. Follow the "Operating instructions for the Drester Dynamic Triple" below and check
that there are no leaks from any of the connections.
This operating manual applies to the complete DRESTER DYNAMIC TRIPLE system.
The DRESTER Gun Cleaner and DRESTER 120 Recycler are described in detail in their own manuals.

Operating instructions for the "Drester Dynamic Triple":

1. FIRST CHECK
* Check that the green lamp is lit and that the oil temperature has dropped to 50C.
(This means that the Recycler is cold, ready to start and may be opened.)
* Check the plastic bag in the Recycler.
(This is a single-use disposable bag and must be replaced after each use. If the bag is full of solvent, check that the
distillate container under the Recycler is empty and then go directly to step 4.)
2. TRANSFERRING SOLVENT
* Start the pumps of the RDX Docking Unit.
(Open the control valve on the right side of the Recycler)
* Turn off the pumps when they start to pump air.
(Turn off the control valve after about 2–3 minutes)
3. SECOND CHECK
* Check that the level indicator of the distillate container is all the way down.
(If not, start the pumps again and let them run for a few more minutes. If the level indicator still does not drop to its lowest level,
then the feed hose is may be blocked or a pump faulty, in which case you should contact an authorised Drester retailer.)
* Check that the plastic bag in the Recycler is full of solvent.
(Roughly up to the level of the ring clamp holding the bag. If not, start the pumps again and let them run for a few more
minutes.
If the bag still is not full, then the feed hose may be blocked or a pump faulty, in which case you should contact an
authorised Drester retailer.)
4. CLOSE THE COVER AND START THE RECYCLER
* Note: Information about settings for time and temperature can be found in the manual for the Recycler, no. 11213, section 5.5.
INSTR: 11143

PREPARATIONS FOR USE

OPERATING MANUAL
REV: 2 / 14-02-21 / TB
GODK:
SID: 5 / 46