Installation Instructions - Invicta Insert 700GA Notice Particulière D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS

To ensure that the walls and floor around the stove do not overheat above 65K (65 degrees Celsius above room
temperature) and for the stove to operate correctly, please follow the installation layout in the diagram.
Ensure that the minimum distances between the stove and enclosed walls, between the "cold air in" convection circuit and
the "hot air" and "out" circuit are maintained. These minimum distances between circuits and surrounding surfaces ensure
that there is enough space around components for proper access for maintenance and replacement of parts as necessary.
Electrical connection of the ventilation system
Power supply 230 V / 50 Hz - power of the ventilation system: 38 W
The device is delivered with a flexible cable, allowing it to be connected to the electrical supply.
An omni-polar separation device should be installed in accordance with local regulations: This device will isolate the
device from the electrical supply network. In particular, the green and yellow earth wires must be connected.
WARNING: if the power cable is damaged in any way, it must be replaced by the manufacturer to prevent the risk of
electric shock.
It may be necessary to remove the stove insert from its housing: ensure that the cable is long enough to not pull on the cable when
removing the woodstove instead from its installation.
BP le 18/02/2020
Wood Stove insert 700 GA
model 967444
The power cable must not be left accessible to users.
Ensure that the power cable is protected by a sheath
between the output in the wall and the entry point into
the stove.
Your Invicta stove is not to be used by children or people
with mental or physical disabilities, unless supervised and
guided by someone responsible for their safety. The stove
should not be operated by inexperienced users unless they
have read or been given prior instructions.
9
Page 3 sur

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P967443Insert 700 grand angle

Table des Matières