MOUNTING RECEIVER ON GARAGE WALL
Fully extend the antenna wire below bottom of case.
Fasten the receiver to an inside garage wall with dry wall
screws provided. A convenient place is alongside the service
door and OUT OF THE REACH OF CHILDREN.
Attach one end of 3-strand bell wire (not supplied) to receiver
terminals 1, 2 and 3. Connect the other end to the three opener
terminals used for push button controls and radio power. Use
insulated staples to secure bell wire between receiver and
opener.
Reconnect power to the opener. The receiver push bar should
light. If it does not, use Transformer Model 85.
NOTE: With the transformer, use a 2-wire connection only.
Attach wire to receiver terminals 1 and 2 and to the opener
terminals used for push button control. Plug the transformer
into receiver and 120 Volt outlet as shown.
Pry open the front panel of receiver case with a coin or a
screwdriver.
1. Press and hold the remote control push button.
2. Then press and release the "Smart" button on the receiver.
The adjacent indicator light will flash once. Release the
remote control push button.
The opener will now operate when the push button on either
the receiver or the remote control transmitter is pressed.
Repeat Steps 1 and 2 for each remote control that will be
used to operate the garage door opener.
NOTE: If the remote control push button is not held down
until the receiver indicator light flashes, the receiver will
not learn the code.
TO ERASE ALL REMOTE CONTROL CODES
• Press and hold the "Smart" code button on the receiver
panel until the indicator light turns off (about 6 seconds). All
the codes the receiver has learned will be erased.
• Repeat Steps 1 and 2 to reprogram the receiver for each
remote control transmitter in use.
WARNING
The use of radios incorporating constant closure
contacts on residential operators with fail-safe infra-
red protectors is prohibited.
The receiver can be set for either constant or momentary
closure on the output contacts. With the jumper in the "MOM"
(Momentary) position, the contacts will close for 1/4 second
regardless of the length of radio transmission. With the jumper
in "CONST" (Constant) position, the contacts will stay closed
as long as the radio continues transmitting.
The receiver is factory set at M.
114A2139
SET RECEIVER TO MATCH REMOTE CONTROL(S) CODE
TO SET OUTPUT DURATION
Jumper
Output
Duration
Terminals
Circuit
Board
CAUTION
© 1996, The Chamberlain Group, Inc.
All Rights Reserved
Universal Radio
Control (Top)
1
2
3
The Chamberlain Group, Inc.
Output Duration Jumper
8/23/94
WARNING
Jumper
Output
Duration
Terminals
Circuit
Board
MOMENTARY
OPERATION
MOMENTARY
OPERATION
Contacteur
Bornes de
durée de mise
sous tension
Bornes de
durée de mise
Mounting Holes
WALL
PUSH
BUTTON
OPENER
Common
Push Button
Radio Pwr.
24v
#3 Connection
(optional)
Model 85
Transformer
To Wall Outlet
Indicator Light
Transmitter
Smart
Push Button
Button
Option
Jumper
The Chamberlain Group, Inc.
Output Duration Jumper
8/23/94
Jumper
Output
Duration
Terminals
Circuit
Board
Circuit
Board
CONSTANT
OPERATION
Contacteur
Printed in Mexico
TRANS
PRIMARY
Jumper
Output
Duration
Terminals
CONSTANT
OPERATION
Contacteur
Bornes de
Co
durée de mise
sous tension
Bornes
durée de