Electrolux 136936003 Instructions D'installation page 5

Sécheuse á chargement frontal
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical Requirements
for Electric Dryer
NOTE
Because of potentially inconsistent voltage
capabilities, the use of this dryer with power
created by gas powered generators, solar
powered generators, wind powered genera-
tors or any other generator other than the local
utility company is not recommended.
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or
circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT
operate a washer and a dryer on the same
circuit.
POWER SUPPLY - 3-wire or 4-wire,
208-240 volt, single phase, 60 Hz,
Alternating Current.
IMPORTANT
This dryer is internally grounded to neu-
tral unless it was manufactured for sale in
Canada.
Only a 4-conductor cord shall be used when
the appliance is installed in a location where
grounding through the neutral conductor is
prohibited. Grounding through the neutral
link is prohibited for: (1) new branch circuit
installations, (2) mobile homes, (3) recre-
ational vehicles, and (4) areas where local
codes do not permit grounding through the
neutral.
OUTLET RECEPTACLE - NEMA 10-30R or
NEMA 14-30R receptacle to be located so
the power supply cord is accessible when
the dryer is in the installed position.
GROUNDING CONNECTION - See
"Grounding requirements" in Electrical
Installation section.
4-WIRE POWER SUPPLY CORD KIT
(not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor power
supply cord NEMA 14-30 type SRDT or ST (as
required) rated at 240 volt AC minimum, 30
Installation Requirements
amp, with 4 open end spade lug connectors
with upturned ends or closed loop connec-
tors and marked for use with clothes dryers.
For 4-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A 4-WIRE
SYSTEM.
Dryers manufactured for sale in Canada have
factory-installed, 4-wire power supply cord
(NEMA 14-30R).
3-WIRE POWER SUPPLY CORD KIT
(not supplied)
The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at
240 volt AC minimum, 30 amp, with 3 open
end spade lug connectors with upturned ends
or closed loop connectors and marked for use
with clothes dryers. For 3-wire cord connec-
tion instructions see ELECTRICAL CONNEC-
TIONS FOR A 3-WIRE SYSTEM.
Improper grounding of the dryer may cause
serious injury or death. Check with a licensed
electrician if you are in doubt as to whether
the appliance is properly grounded.
NOTE
3-wire receptacle
(NEMA type 10-30R)
WARNING
5

Publicité

Table des Matières
loading

Table des Matières