Scope Of Delivery; Principle Of Operation Application; Mechanical Installation - evenes EV-ZUP 15 PLUS Notice De Montage Et De Mise En Service

Masquer les pouces Voir aussi pour EV-ZUP 15 PLUS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 | TECHNICAL DATA
2.4

Scope of delivery

• Pump
• Thermal insulation shell
• Connector
• Installation and operating instructions
3 | PRINCIPLE OF OPERATION
Application
This circulator is suitable for drinking water only.
4 | INSTALLATION
4.1

Mechanical Installation

Danger:
Before starting work, make sure that the pump has been disconnected from the power supply.
Installation site (Fig. 2)
Provide a weatherproof, frost-free, dust-free and well-ventilated room for the installation.
Choose an installation site that is easily accessible.
Caution:
Dirt can cause the pump to fail. Flush the pipe system before installation.
Note:
The stop valve and non-return valve are pre-installed have to be installed additionally.
1. Prepare the installation site so that the pump can be installed without being exposed to mechanical
stresses.
2. Choose the right installation position – only as shown in (Fig. 2 A). The arrow on the back of the housing
indicates the direction of flow.
Turn the motor head or remove it (Fig. 3)
3. Release the union nut – unscrew it completely if necessary.
18
SECONDARY HOT WATER CIRCULATION PUMP EV-ZUP 15 PLUS

Publicité

Table des Matières
loading

Table des Matières