Unic TANGO S duo Caractéristiques Techniques page 174

Table des Matières

Publicité

19/02/08
34
Wrong direction of left piston
35
Rising of left piston
Safety Time out
36
Left piston blocked
or
Simultaneous failures of fork
sensor and Down Position sensor
37
Backward time out safety of
Left piston
Fork sensor of Left piston
38
41
Fork sensor of Right piston
42
Down Position sensor of Right
piston
43
No Rising of Right piston
44
Wrong direction of Right piston
45
Rising of Right piston
Safety Time out
46
Right piston blocked
or
Simultaneous failures of fork
sensor and Down Position sensor
47
Backward time out safety of
Right piston
Fork sensor of Left piston
48
50
Thermostatic probe of Coffee boiler
disconnected
60
Thermostatic probe of Steam boiler
disconnected
70
Thermostatic probe of Unit
disconnected
51
Thermostatic probe of Coffee boiler
Short cut
61
Thermostatic probe of Steam boiler
Short cut
71
Thermostatic probe of Unit Short
cut
80
Thermostatic probe of steam boiler disconnected or short cut
Réf NT01-08
Wrong connection of motor wires.
After 0/1 display of code 36
Rising time too long, over 3 sec
Piston blocked: less than 5 impulses after the
starting and current > 8A
Fork sensor and Down Position sensor switched
off or faulty Or after a code 32 or 34
Fork sensor failure during the backward step
Fork sensor failure during auto control
No impulse from fork sensor when Right piston
goes up
No signal from Down Position sensor with motor
consumption > 0,5 A and after a safety time of
3 sec.
After 0/1 display of code 46
No current consumption from the motor<0,5A
during 3 seconds.
Motor disconnected or not supplied
Wrong connection of motor wires.
After 0/1 display of code 36
Rising time too long, over 3 sec
Piston blocked: less than 5 impulses after the
starting and current > 8A
Fork sensor and Down Position sensor switched
off or faulty Or after a code 42 or 44
Fork sensor failure during the backward step
Fork sensor failure during auto control
No signal from Thermostatic probe of Coffee boiler
(Display shows TC=0)
No signal from Thermostatic probe of Steam
boiler (Display shows TV=0)
No signal from Thermostatic probe of Unit
(Display shows TG=0)
Thermostatic probe of Coffee boiler Short cut
or wiring short cut (Display shows TC=140)
Thermostatic probe of Steam boiler Short cut or
wiring short cut (Display shows TV=140)
Thermostatic probe of Unit Short cut or wiring
short cut (Display shows TG=140).
Auto control
Coffee cycle
Auto control
Coffee cycle
Auto control
Coffee cycle
Coffee cycle
Auto control
Auto control
Coffee cycle
Auto control
Coffee cycle
Auto control
Coffee cycle
Auto control
Coffee cycle
Auto control
Coffee cycle
Coffee cycle
Auto control
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent