ERROR
INVOLVED COMPONENTS
CODE
1
High Level probe
2
High and low level probes
3
Low level probe
4
Turntable rotation
5
Overheating safety of coffee boiler Safety thermostat released
6
Overheating safety of steam boiler Safety thermostat released
7
Overheating safety of unit
8
Cleaning cap
9
Coffee drawer
10
Descent of Left piston
Safety Time out
11
Descent of Right piston
Safety Time out
15
Safety of decaffeinated door
16
Fuse N°1 cut
17
Fuse N°2 cut
18
Fuse N°3 cut
20
Fuse N°8 cut
21
Fuse N°9 cut
22
Data card which is not adapted to the CPU version
31
Fork sensor
32
Down Position sensor of Left piston No signal from Down Position sensor with motor
33
No Rising of Left piston
Réf NT01-08
TANGO ERROR CODES
SOFTWARE VERSION FROM V192
Disconnected
Disconnected
Disconnected when the high level probe is on
water
Wrong positioning
No Rotation or Rotation time too long
110°C Safety thermostat released
Cleaning cap removed
Coffee drawer removed
No current consumption from the motor<0,5A
during 3 seconds. Motor disconnected or not
supplied
No current consumption from the motor<0,5A
during 3 seconds. Motor disconnected or not
supplied
Door opened
No 24 Vac power supply to solenoid valves
No 24 Vac power supply to motors
No 230 Vac power supply
No 24 Vdc power supply to piston driver
No 24 Vdc power supply to turntable driver
No impulse from fork sensor when left piston
goes up
consumption > 0,5 A and after a safety time of
3 sec.
After 0/1 display of code 36
No current consumption from the motor<0,5A
during 3 seconds.
Motor disconnected or not supplied
CAUSES
CIRCUMTANCES
Permanent
Permanent
Permanent
During the rotation
Permanent
Permanent
Permanent
Permanent
Permanent
Auto control
Coffee cycle
Auto control
Coffee cycle
Permanent
Permanent
Permanent
Permanent
Permanent
Permanent
Auto control
Coffee cycle
Auto control
Coffee cycle