Télécharger Imprimer la page

Hanhart PRISMA 200 Mode D'emploi & Garantie page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SELECT
TIMER 1
TIMER 2
DISPL.
START - STOP
INDEX
a) Reset
b) Toggling between the time units SEC and MIN
c) Start/Stop function
d) Stop-watch, countdown and clock time
e) FLYBACK function
f) Automatic Repeat function
g) Pre-setting the countdown time
h) Setting the clock time
a) Reset (delete all values)
By simultaneously pressing the START/STOP and the FLY-
BACK-RESET keys on the upper side of the case, all time
values and the programmed memory are deleted. Afterwards,
the display shows Timer 1.
b) Toggling between time units (SEC. & MIN.)
Pressing and holding down of SET/DIGIT-key during effecting
of Reset at the same time by means of START/STOP- and
RESET-keys.
The selected time unit will be shown in the display as:
sec. for 9 hours, 59 minutes, 59 seconds, 9/1O second
or min. for 9999,99 min
c) Start/Stop function
- Combined START or STOP of both timers by means of the large
START/STOP key.
- Separate START/STOP function by means of the TIMER 1 and
TIMER 2 keys. An active timer is indicated in the display by the
symbol ;t .
d) Stop-watch, countdown, and clock time
- By repeatedly pressing the DISPLAY/SELECT key, the clock
time (symbol: CLOCK), Timer 1 (T 1), or Timer 2 (T 2) may be
selected.
SET/DIGIT
START - STOP
AUTO-REP
- If no value has been entered when the timer is started (START/
STOP, then either T 1 or T 2), the timer selected counts from
zero upward in the normal stop-watch manner.
- If a value has been entered when the timer is started, then the
timer selected counts down from the value entered; at -3, -2,
and -1 time units, a short signal is sounded, and at zero a long
zero-signal.
- The two timers may be used simultaneously in either function,
i. e., one may be used as a stop-watch while the other is in the
countdown function.
e) FLYBACK function
- The Flyback function occurs when a timer in the countdown
function reaches zero; the counting process then begins again
from the previously entered value.
- The timer which is displayed may also be reset manually by
briefly pressing the upper case key ("flying reset").
f) Automatic-Repeat
- A timer which has just emitted a zero-signal is deactivated, and
the other timer is activated in its place.
- This process can be repeated indefinitely. By means of the
SET/DIGIT-AUTOREP key, the Automatic Repeat function can be
toggled on or off.
- When on, the symbol AUTO appears in the display under the
function window.
- The AUTO function can only be used when a value is entered
into both timers.
- The procedure can be started either with Timer 1 or Timer 2. It
is pointless to start with the combined START/STOP key.
g) Pre-setting the countdown time
- Select the timer desired by pressing the DISPLAY/SELECT key.
- Select the digit to be entered by pressing the SET/DIGIT key, the
digit selected will flash.
21

Publicité

loading

Ce manuel est également adapté pour:

Prisma 400