TROUBLESHOOTING PROCEDURES FOR GENOVA
Issue
Cause
After installation,
1. The power source is not turned ON.
the unit doesn't
is not connecting properly.
3. The switch board and control board wirings are
disconnected.
4. The wires on control board are loose.
5. The switch board or control board is defective.
1. The blower is defective, possible seized.
but motor is not
2. The thermally protected system detects if the
turning.
motor is too hot to operate and shuts the motor
down.
3. Damaged capacitor.
4. The blower wire is not connected.
The unit is
1. The blower is not secure in place.
vibrating.
2. Damaged blower wheel.
3. The hood is not secured in place.
The motor is
1. Defective halogen bulb.
2. The light bulb is loose.
lights are not.
3. The wires on the control board are loose.
The hood is
1. The hood might be hanging too high from the
not venting out
properly.
2. Wind from opened windows or opened doors in
of the hood.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting.
vibrating.
RF Remote
1. Battery is dead
control does not
2. Poor communication with the hood
3. RF remote lost communication with hood
What to do
power is ON.
connected properly.
board and control board are connected
properly.
connected properly.
5. Change the switch board or control board.
1. Change the blower.
2. The motor will function properly after the
thermally protected system cool down.
3. Change the capacitor.
molex connector.
1. Tighten the blower screws in place.
2. Change the blower.
1. Change the halogen bulb.
2. Tighten the light bulb.
connected properly.
the bottom of the hood within 24" and 32"
range.
2. Close all the windows and doors to eliminate
duct opening.
5. Change the ducting to correct size.
1. Replace battery with type A23 12v
2. Remote control must be within 15 ft of hood
3. Reset hood and remote by switching power
remote on counter top near hood and switch
20