|Adapter Card Information:
|Vendor/Product ID:
|
Serial Number: 00000000
|
WWN: 0000000000000000
|Additional IOA Data: 00000000 00000000 00000000 00000000 00000000
+--------------------------------------------------------------------------------+

Exemple de journal des erreurs relatives aux grappes

Exemple de journal des erreurs relatives aux grappes
Le journal des erreurs relatives aux grappes prend la forme suivante :
+--------------------------------------------------------------------------------+
|0001:61:01.0: 9030: Array no longer protected due to missing or failed disk unit|
|--------------------------------------------------------------------------------|
| RAID 10 Array Configuration: 2:255:0:0
|--------------------------------------------------------------------------------|
| Exposed Array Member 0:
| Vendor/Product ID: IBM
|
Serial Number: E3V1WEAB
|
WWN: 5000CCA00336F4AC
| Current Location: 2:0:4:0
| Expected Location: 2:0:4:0
|--------------------------------------------------------------------------------|
| Array Member 1:
| Vendor/Product ID: IBM
|
Serial Number: E3V0J55B
|
WWN: 5005076C0400C703
| Current Location: 2:0:5:0
| Expected Location: 2:0:5:0
+--------------------------------------------------------------------------------+

Exemple de journal des erreurs relatives au cache

Exemple de journal des erreurs relatives au cache
Le journal des erreurs relatives à au cache prend la forme suivante :
+--------------------------------------------------------------------------------+
|0001:61:01.0: 9010: Cache data associated with attached devices cannot be found |
|-----Current Configuration-----
|Cache Directory Card Information:
|Vendor/Product ID: IBM
|
Serial Number: 03060038
|
WWN: 5005076C03023F00
|Adapter Card Information:
|Vendor/Product ID: IBM
|
Serial Number: 03060038
|
WWN: 5005076C03023F00
|-----Expected Configuration-----
|Cache Directory Card Information:
|Vendor/Product ID:
|
Serial Number:
|
WWN: 0000000000000000
|Adapter Card Information:
|Vendor/Product ID: IBM
|
Serial Number: 03060038
|
WWN: 5005076C03023F00
|Additional IOA Data: 00000000 00000000 152101D0
+--------------------------------------------------------------------------------+
Identification des incidents liés aux grappes de disques
Un incident de grappe de disque est identifié par un code de référence d'unité (URC) unique.
Un code de référence d'unité (URC) permet d'indiquer l'incident produit. Il sert à déterminer la MAP à
appliquer.
IC35L036UCDY10-0
IC35L036UCDY10-0
5703001
5703001
5703001
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|