Module Installation - Wolf TM15TFS Guide D'installation

Masquer les pouces Voir aussi pour TM15TFS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
SP EC I FI C AT IO N S
Electrical
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design, are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.
Teppanyaki Module
I NS TA LLATIO N
330
457
mm
mm
178
mm
SIDE VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
64 mm
MIN
356
495
mm
mm
64 mm
MIN
COUNTERTOP CUT-OUT
762
mm
E
FRONT VIEW
INS TA L L ATIO N

Module Installation

Remove the unit and components from the shipping
package and recycle packing materials.
Lower the unit into the opening. Center with the front par-
allel to the edge of the countertop.
Troubleshooting
IMPORTANT NOTE:
If the unit does not operate properly,
follow these troubleshooting steps:
Verify electrical power is supplied to the unit.
If the unit does not operate properly, contact Wolf factory
certified service. Do not attempt to repair the unit. Wolf
is not responsible for service required to correct a faulty
installation.
wolfappliance.com
|
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gm15tfsVp414111+Sm15tfs

Table des Matières