8.0 Fault Indication and troubleshooting

Fault Indication
Potential Cause
Pump turned off/disconnected or valves
No Flow
closed
Sense wire disconnected from cell
Salt level in pool has dropped too low
Low salt
Pool water temperature is low
Cell has failed
No Power to Controller
Display blank
Fuse blown
Cables not connected to cell
Low/No chlorine
production
Timer period too short
Chlorine output level too low
Filter needs backwashing
Pool stabiliser too low
Salt level too low
Water Temperature below 15 deg
Excessive Salt Level (Above 10,000 ppm)
Clock loses time
Battery life expired
when mains power
removed
INST322 – CERTIKIN CTX SALT CHLORINATOR Instructions V02_14
Remedy
Ensure valves/pump on
Connect sense wire to cell
See section 7.5 above
Increase salt level or raise water
temperature
Call a technician
Ensure mains power available
Call a technician
Connect cables
Increase timer period
Increase chlorine output
Backwash filter
Get Stabiliser between 30 and 60
ppm
Increase salt to above 4000ppm
Increase water temperature or
salt level
Chlorinator cuts out on overload,
reduce salt level to 4000 ppm
Call a technician