P1P2 Connection (AZAI6WSPDKC)

The DKN Plus Adaptor for VRV/SkyAir units has 4 connecting wires: 2 for communication with the indoor unit (red and black)
and 2 for the power supply. Follow these steps to connect them:
1.
Disconnect the indoor unit power.
Connect the DKN to the terminals of the indoor unit using the A+B supplied cable, X35A/X18A/X9A (depending on
2.
the indoor unit) and P1 P2.
3.
Power the indoor unit. Check the LEDs (see LED Operation section).
The
LED of the DKN Cloud Wi-Fi Adaptor for VRV/SkyAir stays blinking in green when the connection is correct.
Note: To facilitate the access to the DKN Cloud Wi-Fi Adaptor for VRV/SkyAir units, place it in an accessible location.
Note: For FXTQ_PA(B) and FTX_PA(B) indoor units, use the X9A terminal on the A2P PCB for power supply.

S21 Connection (AZAI6WSPDKC)

The DKN Plus Adaptor for Ductless units has one wiring cable. Follow these steps to connect it:
1.
Disconnect the indoor unit power.
Connect the A+C supplied cable to S21 connector on the indoor unit or an accessory adapter (ordered separately).
2.
3.
Power the indoor unit. Check the LEDs (see LED Operation section).
T h e
LED of the DKN Residential Cloud Wi-Fi Adaptor for Ductless stays blinking in green when the connection is
correct.
Note: To facilitate the access to the DKN Residential Cloud Wi-Fi Adaptor for Ductless units, place it in an accessible location.
+
A
B
P1 P2
X35A
A
+
C
S21
21