Configurazione con WRD + Leonardo OFF-GRID
List displayed:
WI.SETUP:
|
|
System Type:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GE Power:
1.4 Kw
|
|
|
MeterPort:
---
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AC Charger:
OFF
WRM Feed-In:
|
|
|
Web SetPoint:
TA Position: Pre PV
|
|
|
Max Pw Grid:
|
Ubat GE Start:
|
|
|
Ubat GE Hist:
|
|
|
|
RESET:
RUN
UPDATE FW:
---
Device:
Address:
AutoConf:
---
Value:
Settable value and descriptions:
Set the type of the installed system:
1-4K-LI: Provides the presence of WRM, recharging from AC-IN
---
is not allowed, feeding into the grid is not admitted.
2-PRO-LI: Provides the presence of PV-On Grid,feeding into the
grid is not admitted.
3-GE-LI: For Use with a Genset. The Meter port is
start the Genset. Is not allowed feeding
Charging power defined by the GE Power field.
4-FIAMM-R: Provides the presence of PV-OnGrid, feeding
the grid admitted.
5-FIAMM-N: Provides the presence of PV-OnGrid,
the grid admitted.
6-PRO-LI_WEB: Provides
into the grid is not admitted. Setting of the power exchanged
with the grid remotely is allowed.
7-CUSTOM: The characteristics of the system are defined by the
following fields.
< --- ~ 25.5 Kw >: If the MeterPort item is set to the Genset
value, it defines the power necessary to charge the battery
pack.
Defines the use of the MeterPort.---:
Port not used
PV Pulse: Used in case of system with AC configuration, to
connect the counter of photovoltaic production.
Genset: By jumpering this port with the AUX1 input using the
cable supplied, it is possible to control the ignition of a
generator when the battery percentage falls below the OFF disk
# 1 threshold. The signal will remain active until the ON
threshold of disk # 1 is reached.
Surplus: By jumpering this port with the AUX1 input via the
cable supplied, it is possible to control the switching on of
a load when the battery exceeds the OFF charge # 2 threshold.
The signal will remain active until the ON charge # 2
threshold is reached.
Allows battery recharging from the AC-IN input
OFF
Enables the input of energy via AC-IN by the WRMs, then PV, once
the OFF charge # 2 threshold has been exceeded.
OFF
Enable the setting of the exchanged power remotely.
<Pre/Post PV>: If present, the external TA sensor defines
whether this is positioned before or after the entry point of
the pre-existing PV system
< --- ~ 25.5 Kw >: It defines the maximum power that can be
taken from the grid.
< --- ~ 56 V >: In Monitor mode, it defines the voltage at which
the contact for turning on the GE is closed. Closing counted if
Vbat + less than GE start.
< 8 ~ 11 V >: In Monitor mode, it defines the contact opening
voltage for switching on the GE. Contact opening when the
battery voltage rises above the GE start + GE Hist value.
RUN : Resets the W-Inverter
RUN: * CAUTION * starts the firmware update procedure of the W-
Inverter device. The firmware update file must be present on the
uSD card.
WRD
Manuale utente
the presence of PV-OnGrid, feeding
22
EN
MENU 8.3
MENU 8.0
used to
into the grid.
into
feeding
into