INSTALLATION PLANNING

Standard Submersible Constant Pressure System

Standard Submersible Constant Pressure System
The above drawing illustrates how a typical submersible pump system should be arranged for a constant
pressure application.
1.
Pump and Motor Assembly: Refer to the Franklin Electric AIM Manual for pump, pipe, and cable sizing
information.
2. Check Valve
3. Pressure Relief Valve: Pressure relief valve must be able to pass full pump flow at 100 PSI.
Risk of bodily injury or property damage.
Pumps can develop very high pressure in some situations. Always install a pressure relief valve able
to pass full pump flow at 100 psi.
Install the pressure relief valve near the pressure tank and route to a drain capable of full system flow.
4. Pressure Tank: Refer to
5. Pressure Gauge
6. Pressure Transducer or Sensor: Install in a vertical position after the pressure tank, and within 6 feet
(1.8 meters) of the tank to minimize pressure fluctuations. There should be no elbows between the tank
and sensor.
7.
SubDrive Connect VFD
8. Power Supply from Circuit Breaker: Single phase, 208/230 VAC +/- 10%.
9. Power to Motor: Single phase or Three-Phase
12
"Minimum Pressure Tank and Supply Pipe Sizing" on page
14.