INSTALLATION
These machines can work in difficult environments. However it is essential to follow the instructions listed below :
• Put the machine on a floor with a maximum inclination of 10°.
• Provide adequate space for the machine's ventilation and easy access to the controls.
• The machine must be protected form the heavy rain and the sun's rays .
• The machine must not be used in an area with metal dusts.
• The machine benefits from an IP23 protection index, which means:
- Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and,
- Protection against the rain inclined at 60% towards the verticale.
These devices can be used outside in accordance with the IP23 protection index.
The manufacturer does not accept responsilbity for damage resulting from incorrect and/or dangerous use of the machine .

MAINTENANCE / RECOMMENDATIONS

Unplug the power source before any maintenance operation.
All operations requiring the removal of the power source's cover must be done by a qualified technician.

1 - Air filter maintenance:

• It is necessary to periodically empty the air filter. To do so, press and hold the orange button below the filter.
• Disassembly:
- Unplug the air supply.
- Grab the tank, press the latch and rotate the bowl 45 degrees to the left.
- Pull the cube downwards and then put it down .
- The filtering part is white, clean or replace it if necessary (ref. 039735).

2 - Periodical maintenance:

• Periodically remove the cover and dust with an air gun. You are advised to have the electrical connections checked by a qualified person, with an
insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, an after sales
service or a qualified person to prevent danger.
• Do not obstruct the machine's air intake, to allow air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn.
CONFORMITY
This equipment complies with the Low Voltage European Standard 2014/35/EU and EMC 2014/30/EU. This complicance is eta-
blished by compying with the harmonised standards : EN60974-1, EN60974-10 and EMC 2014/30/UE.
This hardware is subject to waste collection according to the European directives 2002/96/UE. Do not throw out in a domestic