Technical Data

The technical data of the machine are listed in the table on
page 231–232.
The values given are valid for a nominal voltage [U] of 230 V.
For different voltages and models for specific countries,
these values can vary.

Declaration of Conformity

We declare under our sole responsibility that the product
described under "Technical Data" is in conformity with the fol-
lowing standards or standardization documents: EN 60745
according to the provisions of the directives 2011/65/EU,
2004/108/EC, 2006/42/EC.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
D-70745 Leinfelden-Echterdingen
Dr. Egbert Schneider
Senior Vice President
Engineering
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
24.05.2012

Mounting and Operation

The following table indicates the action objectives for mounting and operation of the power tool. The instructions for each action
objective are shown aside. Depending on the type of application, various instruction combinations are required. Observe the
safety instructions.
Action
Grinding, preparation
Cutting, preparation
Cutting stone, brick and tiles,
preparation (recommenda-
tion)
Sanding with extraction hood,
preparation
2 619 929 K91 | (23.10.12)
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
30°

Noise/Vibration Information

The measured values of the machine are listed in the table on
page 231–232.
Noise and vibrational values (vector sum of three directions)
determined according to EN 60745.
The vibration emission level given in this information sheet
has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with
another. It may be used for a preliminary assessment of expo-
sure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly in-
crease the exposure level over the total working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working pe-
riod.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep hands warm, organise work patterns.