11. WARNING: UNIT MUST BE PROPERLY GROUNDED
12. THIS HEATER MUST HAVE ITS OWN INDEPENDENT CIRCUIT USING A
CORRECTLY RATED CIRCUIT BREAKER AND SUITABLE WIRE, SEE TABLE
RECOMMENDED CABLE.
OPERATING INSTRUCTIONS
1. your new Instant water Heater is flow activated. regulate the knob in one of the 3 setting
power (low, Med, high) the product will switch oN and turn on the hot water tap. the
heating element will work and warm the water only when there is a flow of water through the
appliance.. you will need to allow at least 2.1 liters per minute to flow through the unit in order
to activate the instant heating System. run water through the heater for a few minutes.
2. Be sure to every so often clean the spray head of sediment to assure a smooth water flow.
3. Be sure to every so often clean the incoming water filter.
4. Be sure to install your Instant water Heater in a heated location. the appliance cannot be
installed in areas where the temperature may drop critically and there may be a risk that ice
may form.
5. the user can adjust the hot water temperature regulating the setting power on the unit. the
user can choose till 4 setting poer position:
- Power - heating element is off
- low - only the 1st heating element switches on.
- Med - only the 2nd heating element switches on.
- high - 1st and 2nd heating elements switch on, working together.
ELCB functionality:
the built – in elCB will automatic cut off the power supply in
case there is a current leakage as low as 15ma.
elCB lamp keeps on when elCB function works properly, it
will blink if detects current leakage. in case of thermosat cut
off, the elCB's led will switch off. it will switch on again once
the thermostat start activate again.
Electric leakage test:
to make sure elCB function work properly, this procedure is
recommended to test at least once a month.
after turn on the electricity and water supply,
1. Press the "teSt" button, the unit should trip and cut off the power supply, all leds lamps
should light off.
2. Press the " reSet" button (C), the unit should resume normal function, elCB Blu led
should light on.
if the above mentioned prevail, the elCB functioning in normal condition.
if pressing reSet after you pressed teSt button, the elCB lamp does not switch on, switch
off the mains supply and contact ariston service for repair. NeVer try to repair the unit by yourself.