Temperature Class - SAMES KREMLIN AIRMIX 20C50 GT Consignes D'installation Et Sécurité

Masquer les pouces Voir aussi pour AIRMIX 20C50 GT:
Table des Matières

Publicité

3. INSTALLATION
The pumps are designed to be installed in a spray booth.
DESCRIPTION OF THE LABEL MARKING
Marking in accordance with
the ATEX regulation
SAMES KREMLIN
STAINS FRANCE
TYPE xx
CE
II 2 G
P prod : xx bar / xx psi
P air : 6 bar / 87 psi
Serie / Serial

TEMPERATURE CLASS

Pump, model 10C50 GT:
Pump, model 20C50 GT :
SAMES KREMLIN
Name and address of the manufacturer
Pump model
CE : European conformity
II : group II
Surface equipment meant to an area where explosive atmospheres due to
gas, vapours, mists are liable to appear from time to time in usual operating.
Maximum fluid pressure at the pump outlet
Air supply maximum pressure of the pump motor
Number given by SAMES KREMLIN. The 2 first numbers indicate the
manufacturing year.
Temperature class
T3
Temperature class
T4
: For use in explosive area
2 : class 2
G : gas
Maximum surface temperature
174.8° C / 346.64°F
Maximum surface temperature
111.7°C / 233.06°F
- 3 -
N° : 578.064.120-UK-1904

Publicité

Table des Matières
loading

Table des Matières