Installation distances

C556T
WHEN INSTALLING TURNTABLE (OPTION) the following
installation distances do not apply.
See the separate turntable installation instructions.
Combustible roof
542
INSTALLATION AGAINST COMBUSTIBLE WALLS
Permitted area for
combustible parts
of the building
400
479
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
100
400
Combustible wall
717
Combustible wall
750
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
!
decoration must be at least 1 m.
A separate glass hearth
The dimension diagrams only show
plate (accessory)
the minimum permitted installation
increases the connection
distances for the stove. When con-
height to the chimney by
necting to a steel flue, also note the
10 mm.
safety distance requirements of the
flue. The safety distance between
an uninsulated flue and a combusti-
ble part of the building should be at
least 450 mm.
463
A = height from floor to chimney
140
connection upwards
Ø150
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
35
of hatch
E = minimum height to sloped
ceiling from the centre of the
chimney
100
Air inlet Ø67
INSTALLATION AGAINST FIREWALLS
800
Fire-retardant wall of
brick or concrete
592
850
Fire-retardant wall of
brick or concrete
179**
450**