Binzel Abicor ABIMIG A LW Mode D'emploi page 33

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

®
ABIMIG
5.4.2 PA liner
NOTICE
• New, as yet unused PA liners have to be abridged to the actual length of
the cable assembly.
• For PA liners with an outer diameter of 4.00 mm, the capillary tube in the
distance adaptor must be replaced with a guide tube.
For using aluminium, copper, nickel and stainless steels.
 Fig. 3 Mounting the liner for ABIMIG
1 Disconnect the cable assembly (4) on the machine side and lay it out
straight.
2 Unscrew the nut (6) from the central connector (7).
3 Sharpen the start of the PA liner to an angle of 40° using an
ABICOR BINZEL sharpener.
®
4 ABIMIG
A LW/ABIMIG
Slide the sharpened liner into the contact tip up to the stop.
®
ABIMIG
A T LW:
Slide the sharpened liner into the torch neck liner up to the stop (with the
torch neck mounted).
®
ABIMIG
W T:
Slide the sharpened liner through the wire conduit into the insulating
bush (2) of the torch handle up to the solid stop.
5 Push the retaining nipple, O-ring and nut (6) onto the PA liner.
6 Maintain the pressure on these and tighten the nut (6).
7 Introduce the central connector (7) together with the long PA liner through
the central socket into the wire feeder.
8 Mark the PA liner directly in front of the rolls and disconnect the central
connector again (7).
9 Cut off the PA liner with the ABICOR BINZEL cutter where marked.
10Sharpen the start of the PA liner to an angle of 40° using the
ABICOR BINZEL sharpener.
5 Putting into operation
®
W T torches on page EN-11
®
W or with undivided wire guide:
EN - 13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Abimig a t lwAbimig wAbimig w tAbimig a lw 155Abimig a lw 255Abimig a lw 305 ... Afficher tout

Table des Matières