Datamars Unigizer 15000i Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operation
Select the appropriate pulse speed and output power level
using the selector switch.
When the energizer is switched on, for the first few seconds
the LCD display and the indicator lights show the firmware
version and remote control address setting (only required for
advanced troubleshooting and servicing). After this, the
energizer resumes normal operation. In poor light conditions,
when the selector switch position is changed, the LCD
display illuminates for 20 seconds.
Using the selector switch
Setting
Description
Off
The energizer is off and is not operating.
When the selector switch is in the Off
position, the energizer will not respond to
commands from a remote control.
Battery Test
The battery voltage is displayed by the
indicator lights (all models) and on the
LCD. See
page 9. When this setting is used, the
energizer operates at slow speed
(2.5 seconds between pulses).
Slow Speed -
The energizer operates at slow speed
Day
(2.5 seconds between pulses) during the
Fast Speed -
day and fast speed (1.5 seconds between
Night
pulses) at night. When this setting is used,
the energizer operates at full power. This
setting is for animals active during the
night and is a useful way of conserving
battery power when a battery is being
used to power the energizer.
Fast Speed -
The energizer operates at fast speed
Day
(1.5 seconds between pulses) during the
Slow Speed -
day and slow speed (2.5 seconds between
Night
pulses) at night. When this setting is used,
the energizer operates at full power. This
setting is for animals active during the day
and is a useful way of conserving battery
power when a battery is being used to
power the energizer.
Low Power
The energizer operates at half power and
fast speed (1.5 seconds between pulses).
Full Power
The energizer operates at full power and
fast speed (1.5 seconds between pulses).
8
Testing the battery voltage
Fence voltage
The Indicator lights show the voltage at the energizer's Fence
high energy terminal. Each Indicator light segment represents
an increment of approximately 1 kV (1000 V) of output
voltage. For example, if the first eight Indicator light
segments are illuminated at each pulse, the output voltage is
approximately 8 kV (8000 V).
Red
1
2
3
Note:
If ten Indicator light segments are illuminated, the
output voltage may be more than 10 kV (10,000 V).
If you see only red lights at each pulse and no green lights,
your fence line is very heavily loaded, and you will need to
look for faults on the fence line. See
questions/Troubleshooting
When the energizer is operating, the large digits on the LCD
on
display show the output voltage at the energizer's Fence high
energy terminal.
Note:
If the large digits on the LCD display flash 1.0 kV, this
indicates that the fence voltage is below 1000 V. There is a
serious fault on the fence line. See "How do I locate faults?"
Frequently asked questions/Troubleshooting
in
Alarm feature
If the energizer detects a sudden increase in the load on the
fence, the warning light may flash ( ), the pulse rate may
reduce and the warning buzzer could sound for up to 10
minutes.
For example, this may occur:
if a cutout switch is closed, connecting a heavily loaded
section of the fence to the energizer
if a branch falls on the fence
if the fence or cable connecting energizer to it
experiences a sudden short to ground
if something becomes entangled in the fence.
Green
4
5
6
7
8
9 10
kV
Frequently asked
on page 15.
on page 15.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Unigizer x15iUnigizer 415i

Table des Matières