1. Open the angle valve (only DO 3170D4, DO 3175D4).
The mains plug must not be plugged insein.
2. Completely fill the heater's reservoir with water.
DO 3170D4, DO 3175D4:
Set the flow on the angle valve.
DO 3185D4:
Set the flow with the adjustment screw on the
mixing battery.
5 l/min = 1 l in 12 seconds
3. Only after steps 1 and 2 have been completed:
Insert the mains plug.
Turn the temperature selector to "III" (approx. 85 °C).
Observe the heating until the control lamp goes off.
Heating time: 12–18 minutes
Check the temperature.
Caution: if the safety temperature limiter has switched off
the small water heater, disconnect the mains plug, open the
hot water tap, allow approx. 4 litres of water to run through
and then reconnect the mains plug. The unit is now ready
for operation again.
4. Limiting of the Outlet Temperature
The outlet temperature of the water heater can be
mechanically limited to Step "I" (approx. 40 °C) or
Step "e" (approx. 60 °C).
Information on temperature limiting can be found in
the instructions for use.
5. Saving Energy
Set the temperature selector to "e".
Replacing the Power Supply Cord
I
The power supply cord must be replaced by our customer
service only in order to avoid a hazard.
The mains plug must be pulled before replacing.
en
de
Instructions for Use
Please read the operating instructions carefully before
you use the appliance!
Safety instructions
This appliance is intended for domestic use or for
household-based non-commercial applications. House-
holdbased applications include, e.g. usage in employees
catering facilities for shops, offices, agricultural and
other commercial operations, as well as usage by guests
of guest houses, small hotels and similar residential
establishments.
Risk of electric shock!
Disconnect the power supply immediately if a fault
occurs!
The mixing battery can be hot!
This appliance is not intended for use by persons (includ-
ing children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not
play with the appliance
More detailed information is available in the installation
instructions.
The small water heater heats and stores drinking water up
to approx. 85 °C.
The warm water outlet of the small water heater
serves for pressure equalisation and my be con-
nected only to the pressureless batteries BZ 13051 or
BZ 13061 (below basin) or AM 010100 (above basin).
The outlet temperature can be limited to approx. 40 °C
(Position "I") or approx. 60 °C (Position "e").
The temperature selector also switches on the heating
system.
Position:
Cold
Frost protection
I
Approx. 40 °C
e
Energy saving position approx. 60 °C (light detent)
III Hot water approx. 85 °C
During heating, the control lamp lights and expansion water
drips from the outlet.
At higher temperatures, the unit calcifies more quickly.
Tip: set the temperature selector to "e" in order to operate
the unit economically and reduce limescale.
(light detent)