This Inline Pressure Boosting System is guaranteed by the
manufacturer. In the event of a product failure, it must be
returned to an authorized water system professional for
repairs. Warranty is void if repairs are not made by an
.
authorized technician

ELECTRICAL SAFETY

C A U T I O N
Make sure all ELECTRICAL POWER IS
OFF before connecting any electrical wires.
W A R N I N G
Hazardous voltage.
Can shock, burn, or
cause death.
Disconnect power
before working on
pump, motor or tank.
This control unit is only intended for use with the motor
specified in the Replacement Parts section.
Integral solid state short circuit protection does not
provide branch circuit protection. Branch circuit protection
must be provided in accordance with the National Electric
Code or Canadian Electric Code and local codes.

GENERAL SAFETY

The Franklin Electric Inline Pressure Boosting System has a type
2 enclosure rated for indoor use only.
INLINE SYSTEM KEY FEATURES
SYSTEM FEATURES:
• Pressure boost whenever water is in use
• Hands-off operation
• Simple fault display
• Multiple mounting positions
• Compact design
• Quiet operation
• Single pump/motor/controller design
• Product power rating: 0.33 hp
• Shipping weight: 35 lbs.

INSPECT YOUR SHIPMENT

All Franklin Electric Inline Pressure Boosting Systems are carefully
tested, inspected, and packaged to ensure their arrival in perfect
condition. When the pump is received, examine it closely to make
sure there is no damage that may have occurred in shipping.
If damage is evident, report this immediately to your shipping
carrier and product dealer. The shipping carrier assumes full
responsibility for the shipment's safe arrival. Any claim for
damage to the shipment, either visible or concealed, must be
made through the shipping carrier first.
2
Wire Inline Pressure Boosting
System for correct voltage.
See "Electrical Installation"
section of this manual and
Inline Pressure Boosting System
nameplate.
Meet National Electrical
Code (NEC) or Canadian
Electrical Code (CEC) and
local codes for all wiring.
Follow all pump wiring
instructions provided in
this manual.
Package Includes:
• Inline Pressure Boosting System
• Installation manual
Pro Package Includes:
• All items from the standard package
• Repair wrench
• Horizontal mounting accessory
• 2 gal pressure tank
INSTALLATION
LOCATION OF THE INLINE PRESSURE BOOSTING SYSTEM
Decide on a location for the pump installation that is suitable
based on the enclosure rating of the Inline Pressure Boosting
System. The Inline Pressure Boosting System is only approved
for indoor installation.
Choose a clean, well-ventilated location that provides protection
from freezing, flooding, and excessive heat. In addition, it should
provide access for servicing and allow convenient draining of the
pump housing, tank, and service pipes. A prepared foundation
is not essential, provided the surface is hard and level. The Inline
Pressure Boosting System can be mounted in either a vertical or
horizontal orientation. The unit may be mounted to either a wall
or a floor. When mounting to a wall in a horizontal orientation,
please use the horizontal mounting accessory. The unit must not
be inverted or hung from a horizontal surface.
There must be a minimum of 20" of clearance below the bottom
of the tank to allow access for repair.
N O T I C E
When mounting horizontally, be sure the
tank is properly supported. An optional mounting hook can be
purchased to assist when mounted to a wall horizontally. Do not
hang horizontally from a horizontal surface, such as mounting to
the underside of a floor.
N O T I C E
The Inline Pressure Boosting System is
designed for indoor use only.
PLUMBING, PIPING, and HOSES
In general, keep the suction and discharge lines as large as possible.
Avoid using bends, elbows, and fittings whenever possible. All
suction connections must be airtight, so use pipe compound on all
threaded joints. A suction strainer may be used to help prevent solids
and foreign matter from being drawn into the pump.
The Inline Pressure Boosting System pump is designed to be
used with clean water only.
WATER SUPPLY REQUIREMENT
The Inline Pressure Boosting System is not designed to draw/
lift water from a source below the pumping unit. There is not an
incoming flow requirement, other than that the system needs
to be supplied with a constant supply of water to keep the unit
completely full of water at all times. It is recommended that the
system be supplied with an inlet line of ¾" diameter or larger.
SUCTION PIPING
When the pump is located at a distance from the water source,
the suction piping may have to be increased in diameter to
reduce friction loss. The friction loss in a system increases:
1)
As the flow rate increases
2)
As the piping size decreases
Refer to the included Inline Pressure Boosting System's
performance tables (Appendix 1) and friction loss tables

Publicité