TECHNICAL DATA

DESCRIPTION
Heating
Heat input
Maximum heat output (80/60°)
Maximum heat output (50/30°)
Minimum heat input
Minimum heat output (80°/60°)
Minimum heat output (50°/30°)
Nominal Range Rated heat output (Qn)
Minimum Range Rated heat output (Qm)
DHW
Heat input
Maximum heat output (*)
Minimum heat input
Minimum heat output (*)
(*) average value of various DHW operating conditions
Useful efficiency (Pn max - Pn min)
Efficiency 30% (47° return)
Combustion performance
Useful efficiency Pn max - Pn min (50°/30°)
Useful efficiency 30% (30° return)
Average Range Rated efficiency Pn (80°/60°)
Average Range Rated efficiency Pn (50°/30°)
Electric power (CH)
Electric power (DHW)
Pump electric power
Category
Country of destination
Power supply voltage
Degree of protection
Pressure drops on flue with burner on
Pressure drops on flue with burner off
Heating operation
Pressure - maximum temperature
Minimum pressure for standard operation
Selection field of heating water temperature
Pump: maximum head available
for system capacity
Membrane expansion tank
Expansion tank pre-charge
DHW operation
Maximum pressure
Hot water quantity with ∆t 25°C
with ∆t 30°C
with ∆t 35°C
Selection field of DHW temperature
Flow regulator
Gas pressure
Methane gas nominal pressure (G20)
LPG liquid gas nominal pressure (G31)
Hydraulic connections
Heating input - output
DHW input-output
Gas input
(+) The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation
language.
14
Mynute Boiler Green 25 B.S.I. E
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
%
98,0 - 98,2
%
%
%
105,0 - 108,0
%
%
%
W
W
W
V - Hz
230- 50
IP
%
%
bar - °C
bar
0,25 - 0,45
°C
20/45 - 40/80
mbar
l/h
l
bar
bar
l/min
l/min
l/min
°C
l/min
mbar
mbar
Ø
Ø
Ø
Mynute Boiler Green 32 B.S.I. E
25,00
21.500
24,50
21.070
26,25
22.575
6,00
5.160
5,89
5.067
6,48
5.573
25,00
21.500
6,00
5.160
25,00
21.500
25,00
21.500
6,00
5.160
6,00
5.160
97,5 - 98,3
102,3
98,3
105,7 - 107,7
107,1
98,6
105,8
123
123
83
II2H3P
(+)
X5D
1,73
0,11
3 - 90
0,25 - 0,45
20/45 - 40/80
300
1.000
8
1
8
14,3
11,9
10,2
37-60
11
20
37
3/4"
1/2"
3/4"
25,00
21.500
24,38
20.963
26,43
22.726
6,00
5.160
5,90
5.072
6,46
5.557
25,00
21.500
6,00
5.160
32,00
27.520
32,00
27.520
6,00
5.160
6,00
5.160
102,7
97,9
109,3
97,9
106,9
129
137
87
II2H3P
(+)
230- 50
X5D
2,14
0,10
3 - 90
300
1.000
10
1
8
18,3
15,3
13,1
37 - 60
15
20
37
3/4"
1/2"
3/4"

Publicité

Table des Matières
loading