Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

You will need:
A water heater set to 120° F (49° C).
n
A grounded electrical outlet located within 4 ft. (0.9 m)
n
of power cord on back of washer.
Hot and cold water faucets located within 3 ft. (0.9 m)
n
of hot and cold water fill valves on washer, and water
pressure of 5-100 psi (34.5-690 kPa).
A level floor with maximum slope of 1" (25 mm) under entire
n
washer. Installing on carpet is not recommended.
Floor must support washer's total weight (with water
n
and load) of 315 lbs (143 kgs).
IMPORTANT: Do not install, store, or operate washer where it
will be exposed to weather or in temperatures below 32° F
(0° C). Water remaining in washer after use may cause
damage in low temperatures. See "Washer Care" in Washer
User Instructions for winterizing information.
Proper installation is your responsibility.
Recessed area or closet installation
14" max.
(356 mm)
4"
(102 mm)
0"
(0 mm)
Dimensions show recommended spacing allowed, except for
closet door ventilation openings which are minimum required.
Consider allowing more space for ease of installation and
servicing, spacing for companion appliances and clearances
for walls, doors, and floor moldings. Add spacing of 1" (25 mm)
on all sides of washer to reduce noise transfer. If a closet door
or louvered door is installed, top and bottom air openings in
door are required.
All manuals and user guides at all-guides.com
3"
(76 mm)
48 in.
(310 cm
19"
(483 mm)
24 in.
(155 cm
1"
3"
(25 mm)
(76 mm)

DraIN sysTeM

Drain system can be installed using a floor drain, wall standpipe,
floor standpipe, or laundry tub. Select method you need.
IMPORTANT:
To avoid siphoning, no more than 4.5" (113 mm)
of drain hose should be inside standpipe or below the top of
wash tub. Secure drain hose with beaded tie strap (A).
Floor standpipe drain system
4.5"
(113 mm)
A
Minimum diameter for a standpipe drain: 2" (51 mm).
Minimum carry-away capacity: 17 gal. (64 L) per minute.
Some standpipes may require a Standpipe Adapter Kit and
additional drain hose that may be purchased separately. See
"Tools and Parts". Top of standpipe must be at least 39" (991 mm)
high; install no higher than 96" (2.4 m) from bottom of washer.
Installations higher than 96" (2.4 m) require a sump pump system.
Wall standpipe drain system
2
2
)
4.5"
(113 mm)
See requirements for floor standpipe drain system.
2
2
)
Floor drain system
Floor drain system requires a Siphon Break Kit and additional
drain hose that may be purchased separately. See "Tools and
Parts". Minimum siphon break: 28" (711 mm) from bottom of
washer. (Additional hoses might be needed.)
Laundry tub drain system
4.5"
(113 mm)
A
Minimum capacity: 20 gal. (76 L). Top of laundry tub must
be at least 39" (991 mm) above floor; install no higher than
96" (2.4 m) from bottom of washer.
39"
(991 mm)
A
39"
(991 mm)
3

Publicité

Table des Matières
loading