Technical data
Type of power
supply
Environmental class
Encryption
Certifications
Access code
Conformity
EU Directives
8 EN
a fault report is sent to the alarm control panel and the user is
informed. The external power supply is not monitored in this
mode.
During
operation with an external power supply (DIP
switch 3 deactivated), a fault report is sent to the alarm control
panel as soon as this is interrupted. The wireless control panel
is then automatically powered by the batteries. The
corresponding notification on the alarm control panel informs
the user about this. How a battery test can be carried out is
described above.
Type B (50131-1 §9 und 50131-6 §4.1)
external power supply via power supply unit and batteries
inserted as a backup power supply
Type C (50131-1 §9 und 50131-6 §4.1)
battery operation only, without external power supply via
power supply unit
Power supply compliant with
EN50131-1:2006+A1:2009 9.2 and EN50131-6 if installed
correctly together with Secvest Wireless Alarm System
FUAA50xxx
II (EN50131-1 §7, EN50131-3 §7)
– 2) variants
24
16.777.214 (2
EN50131-3
4-digit or 6-digit
The device is compliant with EN 50131-1, EN50131-3:2009,
EN50131-5-3 and EN50131-6 security level 2 if installed
correctly together with Secvest Wireless Alarm System
FUAA50xxx (verified by ANPI).
RED: 2014/53/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU
WEEE: 2012/19/EU, ErP: 2009/125/EC, Low Voltage:
2014/35/EU, General Safety: 2001/95/EC