Technical data

 Dimensions (L x W x H)
 Weight
 Displays
 Operating temperature
 Radio frequency
 Power
 Humidity
 Protection class
 Security level
 Tamper protection
(detection/protection)
 Signals
 Power supply
 "Low battery" error
message
 Power consumption
 Voltage monitoring
120 x 120 x 30 mm
176 g (without batteries), 246 g (with batteries)
4 status LEDs for partitions
-10°C to +55°C
868.6625 MHz
max. 10 mW
max. 94% (non-condensing)
IP54 (indoors)
2 (EN50131-1 §6, EN50131-3 §6)
Type B (EN50131-3 §8.7)
Integrated piezo sounder
3 x AA Alkaline Batteries (Duracell Procell MN1500,
Duracell Industrial ID1500, Energizer E91
(optional 9-15 V DC / 9-12 V AC || PSU external)
< 3.3 V ("low battery" threshold)
100 mA (nominal)
During battery operation without any external power
supply (DIP switch 3 activated), only the voltage
provided by the batteries is monitored.
If the voltage is below the lower threshold of 3.3 V,
Technical data
EN 7