The ice-making cycle is as follows:
− PRODUCTION
EN
The base of the grid assembly is filled with water
and the thermostat remains in the open position.
Once the set temperature has been reached, the cycle for ice ejection from the
grid assembly (J) (~ 40 min.) will begin.
− EJECTION
Once at the correct temperature, the thermostat will close,
1
enabling the heating element and the motor.
The extractor blades will press on the ice until it detaches; the
2
heating element remains enabled.
The blades extract the ice cubes from their seating, pouring
3
them into the tray (B).
The ice production cycle continues until the ice tray (B) has been filled or until the
water in the tank (D) has been used.
7.2.MAINTENANCE MODE
During maintenance operations, the ice-making operations are interrupted. At
this stage, the thermostat (M) (see fig. 1 or fig. 4) must be turned to the "ice
maintaining" position (see fig. 1a). This thermostat setting keeps the ice cubes
in optimum condition, even for long periods. During the maintenance stage, the
thermostat is set to prevent the formation of a layer of ice on the front section of
the tray or on the front of the grid assembly, as well as reducing ice maker power
consumption.
The machine enters maintenance mode when:
− There is no water (REFILL version). Refill the tank to reset the machine to
ice-making mode.
− The tray is full of ice. Empty the tray (even partly), to rest the machine to
ice-making mode.
PLEASE NOTE: Check the water level of the machine on a regular
basis, using the indicator (H), and pour in more water if necessary.
Insufficient water will lead to the production of ice being suspended
or to the production of irregular-shaped cubes, and may even cause
damage to the pump.