2. DESCRIPTION OF APPLIANCE (See Fig. 1, 3, 4)
A) switch
B) ice tray
EN
C) ice level indicator
D) tank
E) solenoid valve
F) pump
G) front panel
H) water level indicator (REFILL version only)
I) condenser
J) grid assembly
K) filler
L) refrigerating system
M) Adjustment thermostat
The label that shows the serial number and technical data is positioned on the inside
of the ice maker, in the top left-hand section. The first four numbers of the serial
number show the year and week in which the machine was built.
3.

INSTALLATION

Make sure that the machine is not damaged in any way. Any damages caused during
transport must be communicated to the retailer in due time and in any case, no
more than 24 hours from the time of delivery. Handle the machine with the utmost
care and attention. Always position the ice maker on a horizontal, flat surface. The
ice maker must be positioned in a dry area, well away from any sources of heat.
Sufficient ventilation must also be guaranteed and, if the machine is to be boxed in,
two openings must be made in its containing unit: the first opening must be made
in correspondence to the slits on the front panel I); the second opening must be
aligned with the front or - preferably - the upper part of the furniture unit. These
openings must be no less than 300 sq. cm. If it is not possible to carry out this
operation, then a gap of at least 50 mm must be left between the top of the ice
maker and the surface above it (see Fig. 2). Leave the machine idle for at least one
hour before putting it into operation. During this time, it is possible to carry out the
initial cleaning operations.
4.
ELECTRICAL CONNECTIONS
Before connecting the machine, make sure that the mains voltage corresponds to
that given on the machine or compressor rating plates.
This machine must be earthed in accordance with the laws in force. Make
sure that the electrical system earthing installation is in perfect working order.
The manufacturer hereby refuses to accept any liability for damages to
people or property arising from the failure to respect this regulation.
The use of adapters, multiple sockets, or extension leads is not recommended.
Should it be necessary to use one of the latter, always use materials that conform
to the safety standards in force and take care not to exceed the current capacity
limits stated on the materials themselves. In the event that the ice maker plug is
not compatible with the socket, it is preferable to replace the socket with another,