Binzel Abicor BRS-FP Mode D'emploi page 47

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BRS-FP/BRS-FPi
Fault
No injection
Tab. 12
Troubleshooting BRS-FP/BRS-FPi
11 Disassembly
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close the compressed air supply.
• Disconnect the power supply.
• Switch off the entire welding system.
NOTICE
• Disassembly must only be carried out by qualified personnel (in Germany, see TRBS 1203).
• Observe the information provided in the following section:
1 Unscrew the screws and remove the cleaning unit and the collecting tray.
2 Unscrew the screws and remove the support from the base.
12 Disposal
To correctly dispose of the product, it must first be disassembled. When disposing of the system, local
regulations, laws, provisions, standards and guidelines must be observed.
 11 Disassembly on page EN-23
12.1 Materials
This product is mainly made of metallic materials, which can be melted in steel and iron works and are thus
almost infinitely recyclable. The plastic materials used are labeled in preparation for their sorting and
separation for later recycling.
12.2 Consumables
Oil, greases and cleaning agents must not contaminate the ground or enter the sewage system. These
substances must be stored, transported and disposed of in suitable containers. Please observe the relevant
local regulations and disposal instructions in the safety data sheets specified by the manufacturer of the
consumables. Contaminated cleaning tools (brushes, rags, etc.) must also be disposed of in accordance with
the information provided by the consumables' manufacturer.
12.3 Packaging
ABICOR BINZEL has reduced the transport packaging to the necessary minimum. The ability to recycle
packaging materials is always considered during their selection.
BAL.0028 • 2017-03-10
Cause
• Check the fill level
• Compressed air supply/hose connections
interrupted
• Directional valve of injection unit does not
open
• Valve actuator does not move
DANGER
 8 Decommissioning on page EN-21.
Troubleshooting
• Top up the anti-spatter fluid
• Check all supply lines leading to the cylinder
and threaded fittings
• Check the signal output of the robot control
• Replace the directional valve
11 Disassembly
EN - 23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Brs-fpi

Table des Matières