Bond in accordance with applicable codes.
Heater
NOTE: Pump model illustrated may differ from your
actual product.
4. Make the Electrical Connections – Canada
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the pump and heater (if included) to a properly
grounded, grounding-type Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD). This will provide additional protection against line-to-ground shock hazard.
NOTE: A label identifying the model number and electrical rating of the whirlpool is located near the
whirlpool pump.
Locate and secure each supplied junction box a minimum of 1-1/2" (38 mm) above the subfloor.
The whirlpool controls and system have been prewired at the factory. A qualified electrician should
make a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains black and white wires
and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A GFCI or RCD.
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor must not be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
1193346-2-A
Junction Box
8
Wire the junction
box as shown.
Ground
Neutral
Provide suitable
strain relief.
Wire Connectors
From Pump
Line
Line
Neutral