Haier AD12MS1ERA Manuel D'utilisation Et D'installation page 8

Masquer les pouces Voir aussi pour AD12MS1ERA:
Table des Matières

Publicité

Safety Precautions
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Indoor temperature
Cooling
Outdoor temperature
Indoor temperature
Heating
Outdoor temperature
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on the indoor PC board is broken please change it with the type of T 6.3A /250VAC(For series 24,28,36,48).
4. The wiring method should be in line with the local wiring standard.
5. The power cable should be:
2
H05RN-F 3G 4.0mm
(For series 12,18,24);
The connecting cable should be:
2
H05RN-F 4G 1.3mm
(For series 12,18,24,28,36,48)
All the cables shall have got the European authentication certificate. During installation, when the connecting cables
break off, it must be assured that the grouding wire is the last one to be broken off.
6. The power cable and connect cable should be self-provided.
7. The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be no
less than 3mm.
8. The indoor unit installation height is at least 2.5m.
9. A leakage breaker must be installed.
10.For AD12MS1ERA and AD12MS1ERA(D),AD18MS1ERA,AD18MS1ERA(D), AD24MS2ERA,AD24MS2ERA(D),
AD28MS2ERA(S),AD28MS2ERA(S)(D),we can get the 4 different ESP through adjust the indoor unit PCB SW1-4 and
SW1-5, please refer below:
SW1
(1)
(2)
(3)
(4)
(5)
-
-
-
OFF OFF
-
-
-
OFF ON
-
-
-
ON OFF
ON ON
-
-
-
Attention: cut off the power supply to adjust the SW1-4, and SW1-5, or else the operation is invalid.
max. DB/WB
32/23 C
min. DB/WB
18/14 C
max. DB/WB
46/26 C
min. DB/WB
10/6 C
max. DB/WB
27 C
min. DB/WB
15 C
max. DB/WB
24/18 C
min. DB/WB
-15 C
Static pressure
(6)
(7)
(8)
-
-
-
10 Pa
-
-
-
30 Pa
50 Pa
-
-
-
-
-
-
70 Pa