Function

An extremely robust and flexible solenoid lock, which monitors the safe
position of one or more entries in a system, for instance, of a guard or
protective door. For this purpose the module is used in combination with
other mechanical modules, for instance, actuator, key and/or padlock mo-
dule. The key and padlock modules can only be installed above the locking
module.
The entries can only be released after the safety of the plant for the opera-
ting personnel has been ensured. The locking modules ZRX/K, ZAX/K and
ZRH/K with manual unlocking can also be used without actuator module
only for releasing keys in a key interlock system. This function is used in
key interlock systems with central shut-off or shut-off outside the system,
for instance in Ex zones, with strong vibration or dirt build-up, etc.
The ZRHC modules contain command and signalling functions which
enable operation directly at the door.
When installing one of the modules e.g. key module 01/K, 01S/K, padlock
module V/K or actuator module B/K above a locking module ZRX/K and/
or ZRH/K, their release only takes place after applying a control signal to
the magnet of the locking module. If emergency or escape unlocking is
required, please refer to data sheet locking module ZRN/K and ZAN/K.
The ZRHC module combines the functions of a guard locking module with
command and signalling functions. Several configurations are available
for integrating command functions into the SAFEMASTER STS/K safety
switch and key transfer system.
Up to 3 control units can be integrated per module. These can consist of il-
luminated pushbuttons and emergency stop pushbuttons. The illuminated
pushbuttons can be provided with different symbols and colours by the
customer. A transparent colour screen and an unlabelled symbol label are
included in the scope of delivery of the illuminated pushbuttons. Further
colour trims and symbol plates for the illuminated pushbuttons are availa-
ble as accessories.
The command and display functions are integrated in the cover and allow
easy connection using flat receptacles or an optional 12-pin M20 circular
connector.
The functions of the interlocking module can be connected via a separate
cable or optionally a separate 19-pin M23 circular connector.
The compression of the guard locking, command and display functions in
one device allows an extremely space-saving design.
14
SAFEMASTER STS/K Locking module ZRX, ZRH, ZAX, ZRHC / 17.03.20 en / 187A