INSTRUCTION MANUAL
Machine Type:
Pneumatic tool with needles - No other use is permitted.
Air Supply Requirements
1. Supply tool with 90 psig (6.3 bar) of clean, dry air. Higher
pressure drastically reduces tool life.
2. Connect tool to air line using pipe, hose and fitting sizes shown
in the diagram below.
3/8" (10mm)
3/8" (10mm)

Lubrication

Use an air line lubricator with SAE #10 oil, adjusted to two drops
per minute. If an air line lubricator cannot be used, add air motor
oil to the inlet once a day.
Operation
For Needle Scaler
1. Remove worn needles from holder and replace with
new needles, making sure the needle heads fit into the
countersunk holes in needle holder.
2. Slide needles through spring and front nosepiece. Check
that driver is not damaged and placed inside housing
correctly.
3. Lubricate entire needle assembly with a light coating of oil.
Maintenance
1. Disassemble and inspect tool every three months if the tool
is used every day. Replace damaged or worn parts.
2. High wear parts are underlined in the parts list.
3. To keep downtime to a minimum, the following service kits
are recommended:
Tune-Up Kit: 8940169838 (CP7125); 8940169996 (CP7115)
Original Instructions
Copyright 2012, Chicago Pneumatic Tool Co. LLC
All rights reserved. Any unauthorized use or copying of the
contents or part thereof is prohibited. This applies in particular to
trademarks, model denominations, part numbers and drawings.
Use only authorized parts. Any damage or malfunction caused
by the use of unauthorized parts is not covered by Warranty or
Product Liability.
1/2" (12 mm)
CA048362 (1/2")
3/8" (10mm)
3/8" (10mm)
3/8" (10mm)
CA048360 (1/2")
CA048361 (1/2")
Technical Data
Air comsumption: 4,7 cfm (2,2 l/s) (CP7125);
4,3 cfm (2 l/s) (CP7115)
Air Pressure 90 psi (6.3 bar)
Bore and Stroke: 1 x 1,3 in. (21 x 33,5 mm) (CP7125);
0,5 x 1,3 in. (14 x 32 mm) (CP7115)
BPM: 4000 (CP7125 & CP7115)
Noise & Vibration Declaration*
Sound pressure level
94 dB(A) (CP7125); 88 dB(A) (CP7115)
uncertainty 3 dB(A), in accordance with EN ISO 15744. For sound
power, add 11 dB(A).
Vibration value
a=19,2 m/s², uncertainty k=2,4 m/s², re. ISO 28927-9 (CP7125)
a=11,4 m/s², uncertainty k=1,4 m/s², re. ISO 28927-9 (CP7115)
Declaration of noise and vibration emission
All values are current as of the date of this publication. For the
latest information please visit cp.com.
These declared values were obtained by laboratory type testing
in accordance with the stated standards and are suitable for
comparison with the declared values of other tools tested in
accordance with the same standards. These declared values are
not adequate for use in risk assessments and values measured in
individual work places may be higher. The actual exposure values
and risk of harm experienced by an individual user are unique
and depend upon the way the user works, the workpiece and
the workstation design, as well upon the exposure time and the
physical condition of the user.
We, Chicago Pneumatic, cannot be held liable for the
consequences of using the declared values, instead of values
reflecting the actual exposure, in an individual risk assessment in a
work place situation over which we have no control.
This tool may cause hand-arm vibration syndrome if its use is
not adequately managed. An EU guide to managing hand-arm
vibration can be found at http://www.humanvibration.com/EU/
VIBGUIDE.htm
We recommend a programme of health surveillance to detect early
symptoms which may relate to noise or vibration exposure, so that
management procedures can be modified to help prevent future
impairment.
MANUFACTURER'S LIMITED WARRANTY
Limited Warranty: The "Products" of the Chicago Pneumatic Tool Co. LLC
("CP") are warranted to be free from defects in material and workmanship
for one year from the date of purchase. This Warranty applies only to
Products purchased new from CP or its authorized dealers. Of course, this
Warranty does not apply to products which have been abused, misused,
modified, or repaired by someone other than CP or its Authorized
Service Representatives. If a CP Product proves defective in material or
workmanship within one year after purchase, return it to any CP Factory
Service Center or Authorized Service Center for CP tools, transportation
prepaid, enclosing your name and address, adequate proof of date of
purchase, and a short description of the defect. CP will, at its option, repair
or replace defective Products free of charge. Repairs or replacements are
warranted as described above for the remainder of the original warranty
period. CP's sole liability and your exclusive remedy under this Warranty
is limited to repair or replacement of the defective Product. (There Are No
Other Warranties Expressed Or Implied And CP Shall Not Be Liable
For Incidental, Consequential, Or Special Damages, Or Any Other
Damages, Costs Or Expenses Excepting Only The Cost Or Expense
Of Repair Or Replacement As Described Above.)