Mitsubishi Electric MSZ-LN18VG2W Notice D'utilisation page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
S
PECIFICATIONS
Indoor
Model
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R32)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor
(Super High/
High/Med./
Noise level
Low./Silent)
Outdoor
Indoor specifi cation for multi connection
Model
Indoor
Cooling
Capacity
Heating
Input
Noise level
Super High/High/Med./Low/
(Sound power level)
Silent
Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
27°C DB
Upper limit
Heating
20°C DB
Lower limit
Wi-Fi interface
Model
Input Voltage
Power consumption
Size H×W×D (mm)
Weight (g)
Transmitter power level (MAX.)
RF channel
Radio protocol
Encryption
Authentication
Software Ver
For Declaration of Conformity, please go to the website below.
http://www.melcloud.com/Support
MSZ-LN18VG2
MSZ-LN25VG2
-
MUZ-LN25VG(HZ)2 MUZ-LN35VG(HZ)2
Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating
kW
-
-
2.5
kW
-
-
0.485
kg
14.5 (W) 15.5 (V, R, B)
25VG2:33 25VGHZ2/35VG2:34
kg
-
25VG2:0.80
kg
-
25VGHZ2:0.85
-
MPa
-
MPa
42/36/29/
45/38/29/
42/36/29/
dB(A)
23/19
24/19
23/19
dB(A)
-
-
46
REGULATION (EU) 2016/2281
MSZ-LN18VG2
Sensible
kW
Latent
kW
kW
kW
dB(A)
58-52-45-39-35
Outdoor
MUZ-LN25/35/50VG2
MUZ-LN25/35VGHZ2
MUZ-LN60VG
MUZ-LN50VGHZ
46°C DB
-10°C DB
24°C DB
18°C WB
-15°C DB
-16°C WB
MAC-567IFB-E
DC12.7 V (from indoor unit)
MAX. 2 W
79×44×18.5
60 (including cable)
17.5 dBm @IEEE 802.11b
1ch ~ 13ch (2412~2472 MHz)
IEEE 802.11b/g/n (20)
AES
WPA2-PSK
XX.00
MSZ-LN35VG2
MUZ-LN50VG2
~ /N, 230 V, 50 Hz
3.2
3.5
4.0
5.0
0.60
0.82
0.82
1.38
35VGHZ2:36
0.85
IP 20
4.17
45/38/29/
43/36/29/
45/38/29/
46/39/35/
24/19
24/19
24/19
31/27
49
49
50
51
MSZ-LN25VG2
(W/V/R/B)
(W/V/R/B)
1.74
0.06
2.00
0.029
58-52-45-39-35
Note:
1. Rating condition
Cooling — Indoor:
46°C DB
Heating — Indoor:
-10°C DB
2. LN18 have no specifi cations for single combination. These
indoor models are only for multi system air conditioner.
24°C DB
As for the specifi cations of multi system, please confi rm
18°C WB
your dealer and/or refer to the catalogue.
-25°C DB
-26°C WB
DB: Dry Bulb
WB: Wet Bulb
W
HEN YOU THINK THAT
TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/
OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
MSZ-LN50VG2
MSZ-LN60VG2
MUZ-LN50VGHZ
6.0
5.0
6.0
1.48
1.38
1.48
15 (W) 16 (V, R, B)
40
55
1.25
1.45
IP 24
2.77
47/39/34/
46/39/35/
47/39/34/
49/45/41/
29/25
31/27
29/25
37/29
54
51
54
MSZ-LN35VG2
(W/V/R/B)
2.42
3.15
0.08
0.35
2.90
4.00
0.029
0.029
58-51-44-39-34
27°C DB, 19°C WB
Outdoor: 35°C DB
20°C DB
Outdoor: 7°C DB, 6°C WB
MUZ-LN60VG
6.1
6.8
1.79
1.81
55
EN
49/45/41/
37/29
55
55
EN-7

Publicité

Table des Matières
loading

Table des Matières