Electrical connection

V.
DE05101, DE06101, DE06111, DE08101
and DE08111 (fixed electrical connection)
Connect the appliance on the terminal strip in
accordance with the connection schematic.
Put on the housing cover and push it onto the
rear wall of the appliance so that the upper and
lower latches engage.
DE04101 and DE10104
Replacing the Power Supply Cord:
The power supply cord must be replaced by our
customer service only in order to avoid a hazard.
The mains plug must be pulled before replacing.
For all appliances
Vent the continuous-flow heater: Fully open
the warm water tap and flush out the appliance
for about 1 minute (G), until bubbles no longer
emerge.
G

After installation

DE05101, DE06101, DE06111, DE08101
and DE08111 (fixed electrical connection)
Switch on the fuses.
DE04101 and DE10104
Insert the plug into the mains socket.
16
en
VI.

Initial rinsing

Open the warm water tap and allow water to
flow for at least 1 minute (flow-rate at least
2 litres per minute). Only then (for safety rea-
sons) will the appliance begin to heat.
Info: The appliance will not heat if the dispensed
water flow is interrupted prematurely. Open the
warm water tap again and allow water to flow
for at least 1 minute.
Tip: Should the appliance not start because of a
reduced flow-rate, remove the perlator, aerator or
similar before starting and repeating the process.
Important: If the continuous-flow heater does not
have sufficient water flow due to low water line
pressure in your domestic plumbing system:
Switch off the circuit-breakers/fuses or remove
the mains plug.
Remove the flow-rate limiter (H1 – H4).
Controlling temperature
The supply temperature (probably lower in winter)
and pressure fluctuations can influence the temper-
ature of the water leaving the tap (see Fig. IV, left:
1 min
pressurised [closed], right: unpressurised [open]).
Turn the valve slowly in the closed direction for
higher temperatures (F1).
Add cold water for lower temperatures (F2).
Hand over the installation and operating instruc-
tions to the user and explain how the appliance
operates.