Use And Maintenance - Samsung HCO6475TG Notice D'utilisation

Table des Matières

Publicité

- Fix the 2 top screws K and screw anchors (Fig.3), without
tightening them completely.
- Place the appliance against the wall, align it in horizontal
position and tighten screws K (Fig.6).
- Once the adjustment has been completed, fix the hood using
the 2 screws C (Fig.7).
- When carrying out the fixing operations, use only screws and
screw anchors suited to the type of wall (e.g. reinforced concrete,
plasterboard etc.).
- If the screws and screw anchors are supplied with the appliance,
make sure that they are suited to the type of wall to which the
hood must be fixed.
• Installation of models with decorative ducts
Take care not to scratch the duct; wear gloves when removing
the protective film. (Fig. 8A). Make sure the electrical power
supply is within the measurements of the decorative connector.
Adjust the width of the support bracket of the top connector
(Fig.8 C). Then fix it to the ceiling so that it is on the same axis
as the hood using screws A (Fig.8 C) adhering to the distance
from the ceiling shown in (Fig.8 B). Connect flange C to the air
exhaust hole using flexible hose L (Fig.8 D).
Slide the top duct into the bottom duct. Pull out the top duct as
far as the bracket and fix it using screws F (Fig.8 C).
• Filter hood
The filters should be fitted to the extraction assembly inside the
hood, by centring them and rotating them 90 degrees, until they
click into place (Fig. 10).

USE AND MAINTENANCE

• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air.
The effective performance of the cooker hood depends on
constant maintenance; the anti-grease filter and the active
carbon filter both require special attention.
• The anti-grease filter is used to trap any grease particles
suspended in the air, therefore is subject to saturation (the
time it takes for the filter to become saturated depends on
the way in which the appliance is used).
- To prevent potential fire hazards, the anti-grease filters
should be washed a minimum of every 2 months (it is
possible to use the dishwasher for this task).
- After a few washes, the colour of the filters may change.
This does not mean they have to be replaced.
If the replacement and washing instructions are not followed,
the anti-grease filters may present a fire hazard.
• The active carbon filters are used to purify the air which
is released back into the room. The filters are not washable
or re-usable and must be replaced at least once every four
months.
The active carbon filter saturation level depends on the
frequency with which the appliance is used, the type of
cooking performed and the regularity with which the anti-
grease filters are cleaned.
• Clean the cooker hood frequently, both inside and outside,
using a cloth which has been dampened with denatured
alcohol or neutral, non-abrasive liquid detergents.
• The light on the cooker hood is designed for use during
cooking and not for general room illumination. Extended
use of the light reduces the average duration of the bulb.
• Replacing halogen light bulbs (Fig. 9).
To replace the halogen light bulbs B, remove the glass panel C
using a lever action on the relevant cracks.
Replace the bulbs with new ones of the same type.
Caution: do not touch the light bulb with bare hands.
• Commands: (Fig.11)
Push-button A = on/off lights switch
Push-button B = on/off cooker hood switch. The appliance
switches on at speed level 1, If the cooker hood is on depress
the push-button for 2 sec. to switch off the cooker hood. If the
cooker hood is at speed level 1 it will not be necessary to depress
the push-button to switch the cooker hood off. Decreases the
motor speed.
Display C = indicates the motor speed level selected and
activates the timer.
Push-button D = switches on the cooker hood. Increases the
motor speed. Touching the key at 3rd speed, the intensive
function runs for 10' , then the appliance go back to work at the
original speed. During this function the display blinks.
Key E = The Timer times the functions on activation for
15 minutes, after which they are switched off. The Timer is
deactivated by re-pressing Key E. When the Timer is activated
the decimal point must flash on the display. The Timer cannot
be activated if the intensive speed is functioning.
The "clean air" function is activated by pressing key E for 2
seconds when the appliance is switched off. This switches the
motor on for 10 minutes every hour at the first speed. During
functioning a rotary movement of the peripheral segments
must be visualised on the display. When this time has passed the
motor switches off and the fixed letter "C" must be visualised on
the display until the motor re-starts after 50 minutes for another
10 minutes and so on. Press any key apart from the light keys
to return to normal functioning. Press key E to deactivate the
function.
• Active carbon/grease filter saturation:
- When display item C flashes, at a speed where it alternates with
the letter F (e.g. 1 and F), the grease filters must be washed.
- When display item C flashes, at a speed where it alternates with
the letter A (e.g. 1 and A), the carbon filters must be replaced.
After the clean filter has been positioned correctly, the electronic
memory must be reset by pressing button A for approximately
5 seconds, until the indication F or A shown on the display C
stops flashing.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
WARNINGS.
- 28 -

Publicité

Table des Matières
loading

Table des Matières