Technical Specifications - Cardin Elettronica YPR302B02 Manuel D'installation

Programmateur électronique monophasé pour la commande de barrières levantes et rideaux àenroulement motorisés
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
Before commencing with the installation of this appliance make sure that you have read
the following instructions carefully. In particular familiarise yourself with the safety devices
required by the system, only then will you be able to use them to great effect.
Not all of the safety devices required by the local safety standards have been taken
into consideration in this manual. The installer must make sure that any eventual safety
devices required by the local standards and regulations have been installed both ahead
of and after the products described in this manual.
This appliance must be used exclusively for the purpose for which it has been made. Any
non authorised modifi cations are to be considered improper and therefore dangerous.
The manufacturer accepts no liability for damage caused by, or situations arising from, the
improper use of these appliances and therefore all work carried out after the delivery of the
appliance is to be considered the complete responsibility of the installer.
These instructions are aimed at professionally qualifi ed "installers of electrical equipment"
in conformity with the local standards and regulations in force.

TECHNICAL SPECIFICATIONS

Power supply
Frequency
Overall power consumption
Nominal current input
Minimum power cable cross section
Motors
Maximum motor power consumption
Operating temperature
Inputs
Powers supply binding posts 230V ac 50-60 Hz
Earth binding post
Antenna binding post
Dynamic button input contact NO
Opening button input contact NO
Closing button input contact NO
Blocking button input NC
Passive safety contact NC
Opening travel limit contact NC
Closing travel limit contact NC
Inverting photocells contact NC
Stop photocells contact NC
Outputs
Power output for 1 motor 600W
Flashing warning lights output 24V ac 10W
Flashing warning lights output 230V ac 80W
Output powering external devices 24V ac 5W
Work time
Maximum programmable time
Pause time
Maximum programmable time
REMARKS
8
ENGLISH
V ac
Hz
W
Amp
2
mm
Nr.
W
°C
-20...+55
sec.
sec.
230
50-60
600
2,8
1
1
350
60
120

Publicité

Table des Matières
loading

Table des Matières