Technical Specification - Hkoenig KB15 Manuel D'utilisation

Masquer les pouces Voir aussi pour KB15:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
CLEANING REMINDING
When the symbol
the unit, always press the TIMER button for more than 5 seconds, this symbol will disappear
from the LCD display window. And the cleaning timer will reset to Zero and reaccount again.
TROUBLESHOOTING
PROBLEM
Symbol"
" flashs.
Symbol"
" display in
LCD display window.
Ice cubes stick together.
Ice making cycle is normal
but no ice is made.

TECHNICAL SPECIFICATION

Model
Protection Type
Power
Ice Making Current
Ice Harvest Current
Refrigerant
Net Weight
Enclosure
ENVIRONMENT
CAUTION:
Do not dispose of this product as it has with other household products. There is a separation
of this waste product into communities, you will need to inform your local authorities about the
places where you can return this product. In fact, electrical and electronic products contain
hazardous substances that have harmful effects on the environment or human health and
should be recycled. The symbol here indicates that electrical and electronic equipment should
be chosen carefully, a wheeled waste container is marked with a cross.
Adeva SAS / H.Koenig Europe - 8 rue Marc Seguin - 77290 Mitry Mory - France
www.hkoenig.com - sav@hkoenig.com - contact@hkoenig.com - Tél: +33 1 64 67 00 05
flashs, means the unit need to be cleaned. And if you have cleaned
POSSIBLE CAUSE
Lack of Water.
There is too much ice.
The ice cycle is too long.
Water temperature in inner
tank is too low.
Ambient
water temperature in inner
tank is too high.
Refrigerant liquid leakage.
Pipe in the cooling system
is blocked.
220-240V/50Hz
Stainless steel
temperature
or
KB15
I
0.7A
1.0 A
R600a/29g
10.7 kg
SOLUTION
Stop the ice maker, fill water, and
press "ON/OFF" button again to
restart the unit.
Remove ice from ice basket.
Stop the ice maker, and restart it
when the ice blocks melt. Select
the small size ice cube selection.
Change the water in the inner
Tank. Temperature of water is
better set between 45℉-90℉ .
Please run the ice maker below
90℉ and pour colder water into
tank.
Verify by a qualified technician.
Verify by a qualified technician.

Publicité

Table des Matières
loading

Table des Matières