WARNING
CONTAMINATION HAZARD
Wear NIOSH-approved
protective gear when
changing filters.
Change filters after
every remediation job.
Change HEPA filter when the filter
indicator light comes on.
Dispose of used filters according to
your local regulations.
Read and understand manual
before use.
Latch
FIGURE 2
Loosening the latches
Pre-filter
Inlet
panel
FIGURE 3
Pre-filter
HEPA filter
FIGURE 4
HEPA filter
07-01489C 2012-05 Warranty 07-00419
READ AND SAVE THESE INSTRUCTIONS
I
NSTRUCTIONS
Setup
1. Unwrap the cord wrap completely
2. Place the HEPA 500 upright (vertical with handle at the top)
3. Plug in to a standard 115 volt outlet. Each HEPA 500 needs 3 amps to operate.
4. To switch the unit on, locate the control panel and turn the variable speed switch
clockwise to start the unit (see "Control Panel" below). Then select
either a maximum (500 CFM) or down to a minimum (250 CFM) airflow rate. To
maintain the optimal CFM, consult the IICRC S520 standards, 10.3.1. See
this manual's "Resources" section (pg.5) for how to get an S520 standards guide.
5.
The HEPA 500 is multi-positional. For more information, see "Specialized
Features" on (pg. 4).
The Control Panel
Auxiliary Outlet
w/GFCI
Variable Speed Control
Loosen 3/8"
Note that the MAX setting is located immediately left of the OFF button, and the MIN
hex head
setting requires an almost 360 degree clockwise turn.
bolt
Change Light
The change light illuminates when you need to change the HEPA filter.
Once the bolt
is loose slide
The Auxiliary Outlet
the latch out-
You can "daisy chain" or interconnect up to 3 HEPA 500s to customize your air filtra-
ward.
tion needs. The unit can conduct a maximum of 12 amps when it is turned off, and 9
amps when it is turned on. That means you can plug other equipment into the unit,
but the amperage is limited.
Red Circuit Breaker Switch
Latch
The primary purpose of the circuit breaker is to protect the machine. It turns the unit
off when more than 12 amps run through the on-unit circuit.
Ground Fault Circuit Interrupter (GFCI)
The GFCI helps protect the user should it detect a sudden "ground fault," the GFCI
will interrupt the electric current. The GFCI will also trip when a short circuit or an
overload occurs.
When the GFCI "trips," unplug the unit, and look for potential hazards standing
water, frayed cords, etc. anything that would cause a surge of electrical current.
Filter
Relocate the unit and plug it into a different outlet. Then push the "reset" button, and
panel
check to see if it's operating; if so, continue use, if not call Dri-Eaz at 800-932-3030.
The Filters
About the filters
The HEPA 500 utilizes a 2-stage filtration system designed with the most advanced
HEPA filtration technology available. The first stage utilizes a pre-filter (Figure 3), and
the second a HEPA filter (Figure 4). The pre-filter captures larger particles, and the
HEPA filter captures 99.97% of smaller particles down to 0.3 microns.
For environments with a high volume of aerosolized particles, you can use 2 prefilters
to extend the life of the HEPA filter. See "Maintenance" for how often to replace filters.
Changing filters
1. With a 3/8" wrench, loosen the 8 latches holding the inlet panel in place. See
Figure 2.
2. Slide the latches outward, away from the center of the inlet panel.
3. Remove the inlet panel.
4. Remove used filters and replace.
See "Maintenance" for how often to replace filters.
Variable speed
control
3
HEPA filter
Change light
Circuit breaker
Dri-Eaz Products, Inc.