Victron energy BlueSolar MPPT 150/85 Manuel page 15

Masquer les pouces Voir aussi pour BlueSolar MPPT 150/85:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
a. To enter the SETUP Menu, press and hold the SETUP-button during 3 seconds.
The "Menu" icon will light up.
b. Press the "-" or "+" button to scroll.
Table 3 below lists in order off appearance all parameters which can be adjusted
when
pressing the "-" button
c. Press SELECT: the parameter to change will now blink.
d. Use the "-" or "+" button to chose the desired value.
e. Press SETUP to confirm the change, the value will stop blinking, and the change is
made
final. With the "-" or "+" button it is now possible to scroll to another parameter that
needs
change.
f. To return to normal mode, press SETUP during 2 seconds.
1) Press SELECT for 4 seconds to reset to original factory settings. After 4 seconds the
charger will re-boot. (The kWh-counter will not be affected).
2).These values can ONLY be changed for the battery number 8 (USr) (User-defined
battery). The values in the table are for a 48V-battery.
3) When Automatic equalisation is "ON", the absorption charge will be followed by a
voltage limited constant current period (see table 3). The text "equalize" will be on.
The current is limited to 8% of the bulk current for all VRLA (Gel or AGM) batteries and
some flooded batteries, and to 25% of the bulk current for all tubular plate batteries.
The bulk current is the rated charger current (85A) unless a lower maximum current
setting has been chosen.
If, as recommended by most battery manufacturers, the bulk charge current does not
exceed 20A per 100Ah battery capacity (i.e. 425Ah for a 85A charger), the 8% limit
translates to max 1,6A per 100Ah battery capacity, and the 25% limit translates to max 5A
per 100Ah capacity.
In case of all VRLA batteries and some flooded batteries (algorithm number 1, 2 or 3)
automatic equalization ends when the voltage limit maxV has been reached, or after
t = (absorption time)/8, whichever comes first.
For all tubular plate batteries automatic equalization ends after t = (absorption time)/2.
4) Press the"select" button for 3 seconds to reset to zero.
The LCD will show "DONE kWh" after a reset.
Warning
Some battery manufacturers do recommend a constant current equalization period,
and others do not. Do not use constant current equalization unless recommend by
the battery supplier.