Accessories Included - Dri-Eaz Dragon X2 Manuel Du Propriétaire

Masquer les pouces Voir aussi pour Dragon X2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

because the heater does not yet have sufficient fuel
to operate.
6. If the burner has not started after the third attempt,
the burner control light will flash red. To reset, press
and hold the BURNER RESET BUTTON for 15
seconds until the light goes out. Now you may repeat
steps 2–5 as necessary until the burner ignites.
Tip: If the unit will not restart after several attempts,
contact Dri-Eaz Service at 800-932-3030.
NOTICE: You should continue to physically check the
Dragon at least once a day during operation. Check for
leaks, and observe the exhaust smoke to ensure that it's
still clear.
CAUTION: Always use clean fuel and a trusted fuel
source to prevent fuel problems. Be sure to replace the
fuel tank cap to prevent moisture or contaminants from
getting into the fuel.
M A I N T E N A N C E
Recommended Maintenance Intervals
NOTICE: Always turn unit off and unplug before
performing any maintenance.
D E S C R I P T I O N
1. Clean the fuel tank.
2. Replace the fuel filter.
3. Service the burner.
4. Inspect the heat exchanger.
1. Cleaning the fuel tank.
The fuel tank should be cleaned out once a year. To
clean the tank, follow these steps:
a. Place an appropriate container beneath the drain
plug to catch any fuel.
b. Remove the drain plug with a wrench.
c. Allow the tank to drain completely.
d. Replace the drain plug.
e. Dispose of waste fuel in accordance with local
regulations.
WARNING! Diesel fuel and diesel/kerosene mixtures
are flammable and potentially explosive. Always turn
off and unplug the Dragon before draining the fuel
tank. Do not smoke while draining fuel. Keep away
from open flame.
2. Replace the fuel filter
Replace the fuel filter once a year. The filter is a spin-on
type and is located inside the right side cabinet behind
the control panel. Replacement fuel filters may be
purchased from Johnston Supply, part no. L41-653. Visit
www.johnstonesupply.com
49-043 F 2011-06 Warranty 07-00424
I N T E R V A L
Yearly
Yearly
Refer to
manufacturer's manual.
Yearly
to locate the nearest
Johnstone dealer. Have rags or paper towels on hand to
clean up any spills, and dispose of the filter and waste
fuel according to local regulations. You must bleed all air
from the fuel lines and allow the filter to fill with fuel
before the burner will ignite. See "Bleeding the fuel line,"
p. 4.
3. Servicing the burner
Copies of the AF/AFG Oil Burner Manual and the
GeniSys Model 7505 Advanced Burner Control Manual,
published by R.W. Becket Corporation, are included with
your Dragon documentation. Please refer to these
documents for information about servicing the burner.
4. Servicing the heat exchanger and combustion
chamber
In time, soot may accumulate in the the heat exchanger
and combustion chamber. To ensure proper operation,
these components should be inspected once a year and
cleaned if necessary by a qualified HVAC technician.
Contact your local distributor or the Dri-Eaz Service
Department at 800-932-3030 for the location of a service
center near you.
5. Cleaning the housing
To clean the Dragon housing, use a cleaner with a
degreasing agent such as Unsmoke Degrease-All.

Accessories Included

3 25 ft. sections of 8 in. (7.6 m × 20 cm) high-
temperature ducting. One end of each duct is fitted
with a sewn-in cuff and integrated belt and buckle.
1 thermostat with 60 ft. (18.3 m) sensor cord.
1 Owner's Manual (Dri-Eaz)
1 AF/AFG Oil Burner Manual (Becket)
1 GeniSys Model 7505 Advanced Burner Control
Manual (Becket)
Service
For parts and service call your local distributor or the
Dri-Eaz Service Department at 800-932-3030 or
360-757-7776. Copies of the Dragon manual and related
information are available at www.Dri-Eaz.com. Go to
warranty.Dri-Eaz.com to register your purchase.
6
Dri-Eaz Products, Inc.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F429Dragon x2 f429

Table des Matières