4.2

Functional principle

The VISCOFLUX lite Ex drum emptying system consists of a FLUX eccentric worm-
drive pump with motor, a pump centring plate and a follower plate. At the start of the
pumping operation and during the pumping process the follower plate of the pump
lies on the surface of the material in the drum.
A vacuum is created during pumping with the eccentric worm-drive pump, whereby
the follower plate is pressed downwards. The flexible process seal seals the material
and at the same time ensures that there is almost no residue on the walls of the
drum.
To raise the follower plate, compressed air must be blown into the drum. The
compressed air presses the follower plate upwards.
The air pressure stops when the bottom bead on drums with roller beads is reached,
and the follower plate comes to a stop. In this position, the arresting hook will be
hooked to the edge of the drum. The pump is now pulled out of the system. The
follower plate tilts into the dismantling position. The pump centring plate is
dismantled. The follower plate is taken off with the handles.
4.3

Technical data

Dimensions / weight
Dimensions
Drum Ø inside
Eccentric worm-drive
pump
Weight
Material list
Follower plate
Pump centring plate
Process seal
Power supply
Compressed air
Pump motor
34 / 72
mm See dimensional drawing page 35 and 36
mm Standard for drums with Ø 571 mm and for drums
with Ø 571 mm with reduced opening of Ø 545 mm
mm Only eccentric worm-drive pumps with an outer Ø of
50 mm must be used.
kg
Follower plate: approx. 13 kg
Pump centring plate: approx. 6.5 kg
Pump motor and pump vary depending on the pump
length and motor.
1.4404 / 316 Ti
PE conductive
Optionally
NBR conductive or EPDM conductive
6 – 8 bar, dry
On request. Various types of drive are possible.