P A R T S S U P P L I E D
These parts are included with your Flexible Blower:
2 - blower mounting legs*
1 - Parts Bag containing:
(4) wood screws #10 x .50" (12.7mm)*
(4) blower mount brackets
(1) strain relief bushing
(8) screws #10 x .38" (9.7mm)
(8) nuts #10
* For use when mounting Flexible Blower directly to Downdraft
housing. (See Downdraft instruction manual.)
P L A N T H E
I N S T A L L A T I O N
If you choose to mount the Flexible Blower directly to the Down-
draft housing: Remove the inlet cover (taped in place for shipping)
and discard inlet cover. Refer to installation instructions in the
Downdraft manual.
If you choose to mount the Flexible Blower in an inline location,
(such as the cabinet back, cabinet side, or floor joists) - follow
the instructions below.
I N S T A L L F L E X I B L E
B L O W E R I N R E M O T E
L O C A T I O N
NOTE: THE FLEXIBLE BLOWER MUST BE INSTALLED WITHIN
4-FEET (1219mm) OF THE DOWNDRAFT'S ELECTRICAL
PANEL. The Electrical Panel can be mounted directly to the
Downdraft housing - or mounted in a remote location (always
within 4-feet of the Flexible Blower).
10-3/8"
(264)
BLOWER
12-3/4"
INLET
(324)
COVER
5-1/8"
(130)
5"
INLET
(127)
(from
downdraft)
12-3/4"
(324)
1. Position inlet cover over blower wheel. Securely attach the
inlet cover to the blower with 8 screws and 8 nuts from parts
bag. Note that inlet cover is taped to blower for shipping. This
tape may be removed.
2. Determine how the 8" (203mm) round INLET and OUTLET
ductwork will connect to the Flexible Blower. Refer to instal-
lation instructions in the Downdraft manual.
5
11-5/8"
(295)
11-5/8"
(295)
7-3/8"
(187)
OUTLET
(to roof cap
or wall cap)
5-1/4"
(133)
3. Remove the necessary 1/4-20 x .50" (12.7mm) hex head
screws and attach 4 MOUNTING BRACKETS to the Flexible
Blower - using 4 of the 6 POSSIBLE BRACKET MOUNTING
LOCATIONS.
8-IN. (203mm)
ROUND
DUCT
(from
downdraft)
4. Mount Flexible Blower to back of cabinet, floor joist, or
adequate framework (constructed by installer) with appropriate
MOUNTING SCREWS (not included).
5. Connect 8" (203mm) ROUND DUCT from Downdraft housing
to Flexible Blower inlet and from Flexible Blower outlet to roof
or wall cap.
For best performance: Choose the ducting option which allows
the shortest length of ductwork and a minimum number of
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
6. Use strain relief bushing (provided) to attach Flexible Blower
wiring to wiring box on Downdraft's electrical panel and make
wiring connections. (See Downdraft manual for instructions.)
(4) MOUNTING
BRACKETS
attached with
1/4-20 X .50"
(12.7mm) HEX
HEAD SCREWS
(6) MOUNTING
BRACKET
LOCATIONS
MOUNTING SCREWS
(not included)
8-IN. (203mm)
ROUND
DUCT
(to roof cap
or wall cap)