CELL KEY
PREFILTER GUIDES
M5639
Fig. 7. Position of cell key determines orientation of
cell (arrow on key must point downstream).
3. Turn the key around and place it over the opposite
holes. The tab on the bottom fits into the larger hole,
and the screw into the smaller hole. Make sure the
arrow on the key points in the direction of the air flow
(downstream).
4. Tighten the screw into the new hole.
5. Insert the electronic cell. The ionizer section will now
be on the air-entering (upstream) side of the cabinet.
Attach Cell Handle(s)
The cell handles are packed int the installers bag
assembly. They must be installed on the end of the cell
closest to the access door. To install:
1. Orient the cell as it will be when installed. The gray
contact board must be up and the airflow arrow
stamped into the cell must point downstream.
2. Hold the handle sideways and insert the solid tab on
the back of the handle into the slot in the cell. Turn
the handle 90 degrees clockwise to align the divided
tab with the square hole. See Fig. 8.
INSTALL HANDLE ON END OF CELL
CLOSEST TO ACCESS DOOR.
Fig. 8. Install handle on end of cell
closest to access door.
DOWNSTREAM
AIRFLOW
CELL KEY
CELL
SCREW
KEY
ALTERNATE
HOLES FOR
KEY
ROTATE 90
DEGREES
FOLD TAB
TO LOCK
HANDLE
IN PLACE
M6047A
F50F DUCT MOUNTED ELECTRONIC AIR CLEANER
3. Insert the divided tab into the square hole.
4. Fold up the wedge and insert it into the divided tab
to lock the handle in place. If necessary, press with
a blunt instrument like the end of a pliers.
Reassemble Air Cleaner
Insert the electronic cell with the gray contact board up
and the airflow arrow pointing downstream. If the cell
does not slide easily in to the cabinet, check the
orientation of the cell key.
Insert the prefilter on the upstream side of the cabinet
in the guide provided.
Replace the access door. Insert the tab on the bottom
of the door into the slot in the cabinet, then swing it
closed and press into place. The door must be firmly in
place or the air cleaner will not operate.
Complete Wiring
WARNING
Electric shock hazard.
Can cause personal injury.
not
Do
use an extension cord.
• All wiring must comply with local codes and ordinances.
• The line voltage power source must match the voltage and
frequency printed on the label inside the access door.
Plug the F50F directly into the correct voltage and
frequency outlet. See Fig. 9 through 12 for internal
schematic. The F50F will operate properly at any fan
speed on a multispeed or modulated speed system
wired with conduit or plugged in.
NOTE: To reduce the risk of electric shock, this product
has a grounding type plug that has a third
(grounding) pin. This plug will only fit into a
grounding type power outlet. If the plug does not
fit into the outlet, contact a qualified electrician to
install the proper outlet. Do
in any way.
5
not
change the plug
69-0754B—1