Venting Introduction 
This wood stove operates on a
natural draft system, in which the chimney
system pulls air through the stove. This unit
must be installed in accordance with the
following detailed descriptions of venting
techniques; not installing the stove in
accordance with the details listed here can
result in poor stove performance, property
damage, bodily injury or death. Avoid
make‐shift compromises when installing the
venting system. England's Stove Works is
not responsible for any damage incurred
due to a poor or unsafe installation.
Be certain that all aspects of the
venting system are installed to the venting
manufacturer's instructions, particularly the
required clearances to combustibles. Also,
be certain to use an attic radiation shield to
prevent insulation from contacting a chimney
which passes through an attic.
The chimney system is the "engine"
which drives a wood stove, so it is
imperative for proper unit function that the
venting system be installed exactly as
described in the following section.
If questions arise pertaining to the
safe installation of the stove, our Technical
Support line (800‐245‐6489) is available.
Contact your local code official to be certain
your installation meets local and national fire
codes, and if you're uncertain about
how to safely install the stove, we strongly
recommend contacting a local NFI certified
installer to perform the installation.
WARNING: Venting system surfaces get HOT, and
can cause burns if touched. Noncombustible
shielding or guards may be required
WARNING: If Fans are installed in the storage
area, they should not create negative pressures in
the room where the solid fuel-burning appliance is
located
8
INSTALLATION
Venting Guidelines
ALWAYS install vent pipe in strict
adherence to the instructions and
clearances included with your
venting system.
DO NOT connect this wood stove to
a chimney flue which also serves
another appliance.
DO NOT install a flue pipe damper
or any other restrictive device in the
exhaust venting system of this unit.
USE an approved wall thimble when
passing through a wall and a ceiling
support/fire stop when passing
through a ceiling.
INSTALL three sheet metal screws
at every chimney connector joint.
AVOID excessive horizontal runs
and elbows, as both will reduce the
draft of the venting system and will
result in poor stove performance.
INSPECT your venting system
often, to be certain it is clear of
creosote, fly‐ash and other
restrictions.
CLEAN the venting system as
detailed in the maintenance section
of this manual.
ADHERE to the 10‐3‐2 rule regarding
chimney terminations.
INSTALL single wall chimney
connector with the male end down
to prevent creosote leakage. Follow
double wall chimney connector
manufacturer's instructions regarding
proper pipe installation.
The 10-3-2 Rule: The chimney
system must terminate 3.0 ft above
the point where it's centerline
passes through the roof AND the
chimney must terminate 2.0 ft.
above part of the dwelling within a
10 ft. radius of the chimney.