BLOWER AND THERMOSTAT INSTALLATION
Blower Installation
The BM-1376 blower will be mounted to the opening that is located at the bottom
on the rear of the stove. The blower will simply mount to the opening with the five screws
that are installed on the unit.
NOTE: The heat circulation blower on this furnace requires periodic lubrication;
this lubrication should be performed no less than every three months of normal operation.
To properly lubricate the blower, use an eye dropper or similar dispensing device to drip
5-7 droplets of SAE 20 oil into the oil port on the side of the blower motor.
Thermostat Installation
The thermostat, blower and power cord are all prewired (see Figure 4 for
thermostat instructions); however, the thermostat must be connected to the furnace after
installation of the blower. Do this by inserting the probe portion into the stove (remove the
cover first, to reveal the mounting plate) and fastening the thermostat to the unit with the
four screws that are mounted on the furnace.
OPERATING INSTRUCTIONS
Page | 13
Probe thermostat mounts in top rear
(4 screws)
Outside
Air will
connect
beside
blower
Blower mounts on bottom rear
(5 screws)